12
3.PROG/SET
:
FUNC switch:
In display mode
,
PROG/SET key and screen shows Cd00
(General parameter input area).
,
Press PROG key again
and screen shows CE-00 (failure and engineering mode). If
pressed PROG key now, screen would return to display
mode.
SAVE function: In parameter input mode, press PROG/SET key will save
new parameter just input.
4.
READ
:
READ function
:
When display shows Cd-?? (General parameter Input mode) or
CE-?? (Failure display and engineering mode), Press
READ to parameter input mode. Screen showing
previously parameter setting. Change of parameter can be
proceeding.
Back to display function
:
Press READ at parameter input mode can escape
from parameter input mode and not save new parameter.
5.
Key (
<
as shown): SHIFT function
:
press
<
key to swich position of nonius
,
when the nonius is at left
,
press
<
key nonius will be back to
right
,
when accommodate to press
▼、▲
key to modify
parameter in this mode.
6.
▼、▲
key:
Item of display changing
:
Press
▲
,
▼
key at display mode, select required
item.
Parameter selection
:
Press
▲
,
▼
key to change value when screen
shows Cd- (General parameter input area) or CE-
(Failure display and engineering mode). Press and
hold
▲
,
▼
key can progressively increase or
decrease value.
Parameter modification
:
Press
▲
,
▼
key at parameter input mode can
change parameter. Using with SET key to
modify parameter.
Содержание CT-2000ES
Страница 7: ...7 G Control circuit...