38
Download monitor
event log:
Select this option to configure the I-Test to download the event log of the
monitor under test to the I-Test.
i
If download monitor event log is selected in the sequence it will extend the total test time
while the log files are transferred.
!
If I-Test is configured to download the monitor event log the log will be deleted from the
gas monitor after download.
Download monitor
data log:
Select this option to configure the I-Test to download the data log of the
monitor under test to the I-Test.
i
If download monitor data log is selected in the sequence it will extend the total test time
while the log files are transferred. This could cause the time taken for a speedy bump to
be significantly increased.
!
If I-Test is configured to download the monitor data log file the log file will be deleted from
the gas monitor after download.
Expiry Policy:
Expiry policy allows the user to determine how the I-Test should function
should the gas cylinder expiry date be exceeded (see
of cylinder expiry dates).
Reject Cylinder
– Select this option if I-Test should reject an expired cylinder
and not use the cylinder for the tests.
Use Cylinder
- Select this option if I-Test should continue to use the cylinder
after the expiry date.
i
It should be noted that I-Test will order the sequence of tests in the following order where
appropriate if selected:
Configure, Bump Test (either speedy or smart), Calibration, Log Download.