26
3.7.1.1
Edit or create a new profile
To create a new profile or edit an existing one, proceed as follows:
X
Click
New
to create a new profile.
X
To edit an existing profile, click on the cylinder profile in the
Defined Cylinders
list so that it is
highlighted and then click
Edit
.
Alter the following fields as required:
Cylinder type:
To create a new cylinder profile select the required cylinder type from the drop
down list.Cylinder options are tri, quad or quin.
Suitability:
Select the use(s) for which this cylinder is suitable by clicking on the relevant
tick boxes.
Suitability options are speedy bump, smart bump , calibration and cross
calibration.
When calibration is selected speedy bump and smart bump are automatically
selected.
When cross calibration is selected calibration, speedy bump and smart bump
are automatically selected.
Note: Smart bump functionality is only applicable to Gas-Pro, T4 will only
undertake a speedy bump test.
i
Crowcon recommend calibration standard gases are used for calibration functions to
ensure accurate calibration of the gas monitor under test.
Two calibration options enable the flammable sensor in the gas monitor to be
tested with either target gas or, if required, the C
5
H
12
, C
3
H
8
and C
4
H
10
sensors
can be tested with CH
4
when the cross calibration option is selected.
i
Unless the cross calibration option is selected gas monitors must only be bump tested or
calibrated with target gas.
Calibration:
This option should be selected if flammable sensors in all gas monitors to be
tested by I-Test are to be calibrated with target gas only.
For example if flammable sensors in all the monitors are CH
4
and the cylinder
to be used for testing contains CH
4
, then this option should be selected.
Contents
Exit
Unpacking
Set-up
Operating I-Test
I-Test
Manager
Configuring
I-Test
Warranty
Overview
Contacts
Appendices
Troubleshooting
Specification