Page 24
Option 1
Radio User
- Users 101-2000 can be Radio keys (Pendant) if required. Radio keys can be used to Arm/
Disarm all or part of the alarm or they can operate outputs directly. Unlike user codes, a radio key
cannot be assigned to a keypad so if a radio key is assigned to more than one output and the radio key
is operated, all of the outputs assigned to the radio key will turn on.
Option 2
Access Tag/Card User
- Users 1-2000 can be Access Tags or Cards if required. Access Tag or Card
operation requires that the optional Proximity Reader is connected to the panel via a Wiegand Interface
Board. The Proximity Readers can be assigned to any one of the 32 possible keypad addresses. Access
Tag or Card Users can be assigned to operate at multiple keypads and assigned to control multiple
outputs. A keypad can also be assigned to control selected outputs so that an Access Tag or Card User
assigned to multiple outputs (which can in turn be linked to doors) can only operate the door assigned to
the keypad they are using.
Option 3
Both Code and Access Tag/Card User {Tag + PIN}
- Up to 2000 code Users and up 2000 tag or card
Users can be stored in the panel. If the Proximity Reader with the full keypad is installed on the panel, it
is possible to arm/disarm the alarm or gain access through a door by presenting the tag/card at the
reader then entering in the user code {PIN Number}. It MUST be in that order ie Tag then PIN. This
option provides a more secure means of arming or disarming the alarm, or gaining access through a
door, because it requires both the access tag/card plus the PIN number.
Option 4
Either Code or Access Tag/Card User {Tag or PIN}
- Up to 2000 code Users and up 2000 tag or card
Users can be stored in the panel. If the Proximity Reader with the full keypad is installed on the panel, it
is possible to arm/disarm the alarm or gain access through a door by entering in the user code at the
reader or presenting the tag/card at the reader. This option gives two methods of controlling the alarm.
USER AREAS
USER AREAS
- P3E 1-2000E
Option 01 - 32 Assigned to Area 1-32
Option 01
Assigned to Area 1
- If a User has option 1 on, they can Arm/Disarm all zones assigned to Area 1
Option 32
Assigned to Area 32
- If a User has option 32 on, they can Arm/Disarm all zones assigned to Area 32
Any combination of the above areas may be assigned to Users 1-2000.
USER ACCESS OPTIONS
USER ACCESS OPTIONS
- P4E 1-2000E
Option 1 - User can Arm Area
Option 2 - User can Arm Stay Area
Option 3 - User can Disarm Area
Option 4 - User can Disarm Stay Area
Option 5 - User is a Security Guard User
Option 6 - User will Arm Latchkey Mode
Option 7 - User can reset latched Egress Outputs
Option 8 - User can View Event Memory
Option 1
User can Arm Area
- If a User has option 1 on, they can Arm all Areas assigned at location P3E.
Option 2
User can Arm Stay Area
- If a User has option 2 on, they can Arm Stay Mode for all Areas assigned at
location P3E.
Option 3
User can Disarm Area
- If a User has option 3 on, they can Disarm all Areas assigned at location P3E.
Option 4
User can Disarm Stay Area
- If a User has option 4 on, they can Disarm Stay Mode for all Areas
assigned at location P3E.
Option 5
User is a Security Guard User
- If a User has option 5 on, they can Arm all Areas assigned at location
P3E, but they may only Disarm if the panel is currently Armed and in the alarm state.
Option 6
User will Arm Latchkey Mode
- If this option is ON, the User will Arm the alarm in Latchkey Mode.
Latchkey Mode can also be armed by using the <ARM>, <STAY>, <A> or <B> buttons, (see P75E,
P77E, P79E & P81E option 6) or the key-switch (see P120E option 6). If a User with this option ON