![Crow RUNNER 8/64 Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/crow/runner-8-64/runner-8-64_installation-and-programming-manual_2689361029.webp)
Page 29
buss. With the reader connected and the panel in program mode, entering P21E then the Access tag/card number
you wish to enrol, eg 11E for Tag/Card number 11, the keypad will start to beep to indicate that learn mode has
been started. Now present the Access Tag/Card to the reader. Once the Tag/Card number has been received by
the panel and saved, the keypad will stop beeping to indicate learn mode has stopped.
When learning a new access Tag/Card the panel checks all possible locations before saving the new code to
ensure that the code has not already been loaded. If the tag or card already exists, the panel will not terminate
learn mode but instead it will continue looking for a new tag or card to be presented. This allows a new tag or card
to be learnt while existing tags or cards may be in use on the system.
After learning the tag or card, before it will work you MUST select the appropriate option at location P2E (options
2, 3 or 4 must be selected for the tag to work).
DELETE an ACCESS TAG/CARD CODE
DELETE an ACCESS TAG/CARD CODE
- P22E 1-2000E
If you wish to delete a single Access Tag or Card, pressing P22E then the User number while in Program Mode
will delete the stored code against that User, eg P22E 11E will remove the tag or Card stored for User 11.
FIND an ACCESS TAG/CARD LOCATION
FIND an ACCESS TAG/CARD LOCATION
- P23E ENTER
If you have an Access Tag or Card loaded into the panel but are unsure which location (User #), pressing P22E
then ENTER while in Program Mode will start “Find” Mode. The keypad will start to beep to indicate that “Find”
mode has been started. Now present the Access Tag or Card you wish to find to a proximity reader connected to
the panel. If the Tag or Card is in memory the keypad will display the number where the Tag or Card is stored (a
number from 1-2000). The keypad will stop beeping once the memory location has been found.
Manually enter in a Card/Tag Printed Number
P24E 1-2000E -
Enter in the 10 digit printed card/tag number
The Access Tags/Cards come with a printed 10 digit decimal number. To eliminate the need to learn the Tag/card
number via a Prox reader (address P21E) the printed number can be manually entered at this address.
Code/Tag/Radio User Usage Count
P1025E 1-2000E -
A value of 1-254 equals the number of times it can be used. 255 = always
If an access Code, Tag/Card or Radio User has a value between 1-254 programmed at this address the user will
only be able to be used that number of times before it stops working. Every time the User uses their Code, Tag or
Radio button the programmed count will reduce by 1 until it reaches a value of zero. When the value is zero the
User will stop working. If a value of 255 is programmed the user will always work.
Code/Tag/Radio User Start Date
P1026E 1-2000E -
DD:MM:YY The date a Code/Tag will start to function.
If an access Code, Tag/Card or Radio User has a start date programmed at this address the user will only be able
to be used when that start date has been reached. The start date begins at 00:00 on the date programmed. If a
value of 00:00:00 is programmed the start date is ignored.
Code/Tag/Radio User End Date
P1027E 1-2000E -
DD:MM:YY The date a Code/Tag will cease to function.
If an access Code, Tag/Card or Radio User has an end date programmed at this address the user will only be
able to be used until midnight of the programmed date. If a value of 00:00:00 is programmed the end date is
ignored.
Code/Tag/Radio User Start Time
P1028E 1-2000E -
HH:MM The time a Code/Tag will start to function.
If an access Code, Tag/Card or Radio User has a start time programmed at this address the user will only be able
to be used when that start time has been reached. If a value of 00:00 is programmed the start time is ignored.