MANUAL FIRE ALARM BEEPS TO KEYPAD
MANUAL FIRE ALARM BEEPS TO KEYPAD -
P91E 1-32E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
When a keypad Fire Alarm is generated, the alarm can be silent or it can operate the buzzer in the keypad.
MANUAL MEDICAL ALARM BEEPS TO KEYPAD
MANUAL MEDICAL ALARM BEEPS TO KEYPAD -
P92E 1-32E Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
When a keypad Medical Alarm is generated, the alarm can be silent or it can operate the buzzer in the keypad.
WRONG CODE or KEYPAD TAMPER BEEPS TO KEYPAD
WRONG CODE or KEYPAD TAMPER SWITCH ALARM BEEPS TO KEYPAD -
P93E 1-32E
Value = 01-32 for Keypads 1-32
Option 01 = Keypad 1 - Option 32 = Keypad 32
If someone enters in an incorrect code more than 4 times or a Keypad Tamper Switch Alarm is generated, the alarm
can be silent or it can operate the buzzer in the keypad. The selected keypad, e.g. P93E1E for keypad number 1 is
the one at which the alarm has occurred and the options 01-32 are the selected keypads that will beep in alarm.
CHIME ALARM KEYPAD BEEP TIME
CHIME ALARM KEYPAD BEEP TIME -
P94E 1-32E (Value = 0-255 1/10th Second)
When a Chime Zone is activated it can operate an Output and/or beep the keypad buzzer. There is a separate Chime
timer for each of the 32 keypads. If the value is made “0” for a keypad the Chime Zone will not beep the keypad
buzzer. The Keypad Chime Timer can be set to a value from 1-255. The units are in 1/10th second increments. This
means that a value of 10 will beep the keypad buzzer for 1 second.
LCD KEYPAD BACK-LIGHT SETTINGS
LCD KEYPAD BACK-LIGHT SETTING
-
P95E1-32E
Value
=
0-100 = LCD B/L value 0-100%
The LCD and keypad backlight levels can be independently set for every keypad. A value of 0 means no backlight
where a value of 100 is maximum backlight brightness.
FULL LCD KEYPAD DISPLAY OPTIONS
FULL LCD Keypad Display Options
-
P96E 1-32E Value = 1-8
Option 1 = 2 x 20 Display Mode or AAP Logo
Option 2 = Spare
Option 3 = Show LCD System Idle or Keypad Name
Option 4 = Display Armed Areas as numbers
Option 5 = Spare
Option 6 = Spare
Option 7 = Double badge to ARM keypad
Option 8 = Control button operates assigned outputs directly
Option 1
2 x 20 Display Mode or AAP Logo
- If this option is turned On the FULL LCD keypad will show
the AAP Logo plus the current time. If the option is turned Off the display will show the standard 2
lines x 20 character display that includes the Idle or keypad name (see option 3) plus the time and
date.
Option 3
Show LCD System Idle or Keypad Name
- If this option is Off the FULL LCD display will show
the System Idle Name (P25E14E). If it is ON the FULL LCD will display the Keypad Name. To
display the keypad name option 1 must be OFF.
Option 4
Display Armed Areas as numbers
- If this option is On the FULL LCD keypad will show all
Armed Areas as an Area number. This makes checking to see if your Area is armed or disarmed