![Crow RUNNER 8/64 Скачать руководство пользователя страница 25](http://html1.mh-extra.com/html/crow/runner-8-64/runner-8-64_installation-and-programming-manual_2689361025.webp)
Page 25
Disarms the alarm no Latchkey Disarm report will be sent via the dialler. If Latchkey Mode is Armed
and a user with this option turned OFF Disarms the alarm a Latchkey disarm report will be sent to
alert parents when their children have returned home. Reporting of Latchkey Disarm is enabled at
location (P189E option 1). If a Voice report is desired the message is assigned at P176E10E.
Normally you would select a telephone number/s set for domestic or voice reporting to report the
Latchkey disarm signal.
Option 7
User can reset latched Egress Outputs -
If this option is on the user can reset all outputs that
have been turned on by an Egress Input. The outputs will stay on overriding any programmed
output reset times (PO40E) until reset by this code.
Option 8
User can View Event Memory
- If access to memory mode is restricted by turning on option 8 at
location P25E13E, this option allows the user to access memory mode by pressing <MEMORY>
<CODE #> <ENTER>. If this option is off and memory access is restricted, the user cannot view
memory mode.
USER CODE PRIVILEGES
USER CODE PRIVILEGES
- P5E 1-2000E
(see chart on page 96 for the exact program locations)
Option 1 - User can Change Their Code
Option 2 - User can Change All Codes
Option 3 - User can Allow Access to Installer Mode/Edit All Codes
Option 4 - User can Change Telephone Numbers
Option 5 - User can Change Clock Settings
Option 6 - User can Change DTMF Codes
Option 7 - User can Learn New Radio Devices
Option 8 - Spare
Option 1
User can Change Their Code
- If a User has option 1 on, they can access Client Program Mode
and change their code number.
Option 2
User can Change All Codes
- If a User has option 2 on, they can access Client Program Mode
and change All User code numbers.
Option 3
User can Allow access to Installer Mode/Edit All Codes
- If a User has option 3 on, they can
access Client program Mode. From there an Installer with the correct Installer Code can access
Installer Program Mode. The User with this option can also edit all User Codes and associated
parameters as shown in the chart on page 112.
Option 4
User can Change Telephone Numbers
- If a User has option 4 on, they can access Client
Program Mode and change the telephone and call divert numbers.
Option 5
User can Change Clock Settings
- If a User has option 5 on, they can access Client Program
Mode and change the Time & date settings as well as daylight saving sart and finish times.
Option 6
User can Change DTMF Codes
- If a User has option 6 on, they can access Client Program Mode
and change the DTMF Codes. A DTMF Code can be used to remotely Arm/Disarm an Area, turn
Output/s On/Off or Acknowledge a Voice/Domestic alarm.
Option 7
User can Learn New Radio Devices
- If a User has option 7 on, they can access Client Program
Mode and Learn a new Radio Key or Wireless Zone Device. They can also remove radio devices or
find what location number a device is stored at.
USER CODE MISCELLANEOUS OPTIONS
USER CODE MISC OPT.
- P6E 1-2000E
Option 1 - User is Excluded from Global Trouble Reset (see P25E10E option 4)
Option 1
User is Excluded from Global Trouble Reset
- If option 4 is ON at P25E10E then any valid user
can reset trouble alarms. If this option is ON they can only reset trouble alarms in areas associated
with the user.