If Stay Mode is Armed and a Stay Mode delay zone triggers the entry delay it can also beep the keypad buzzer to
warn that the entry delay is counting down and the alarm should be turned off.
ARMED ZONE ENTRY DELAY TIME
ARMED ZONE ENTRY DELAY TIME -
P144E 1-64E (Value 0-9999 Seconds)
Each Zone has it’s own Entry Delay time when in the Full Armed State. The delay can be programmed from 0-9999
seconds in one second increments. If the entry delay is set to “0” the zone will be an instant zone.
STAY MODE ZONE ENTRY DELAY TIME
STAY MODE ZONE ENTRY DELAY TIME -
P145E 1-64E (Value 0-9999 Seconds)
Each Zone has it’s own Entry Delay time when in Stay Mode. The delay can be programmed from 0-9999 seconds in
one second increments. If the entry delay is set to “0” the zone will be an instant zone.
ZONE RE-TRIGGER COUNT
ZONE RE-TRIGGER COUNT -
P146E 1-64E (Value 0-15 Triggers)
Each Zone has it’s own alarm Re-trigger Count. A value of 0 programmed at this location results in unlimited alarms
for that zone during an armed period but a count of 1-15 will shut down the zone once the programmed count has
been reached. Disarming the alarm will reset this count.
Zone Reports using this Area
ZONE REPORTS USING THIS AREA
- P147E 1-64E (Value 0-32 for areas 1-32)
When a zone is in multiple areas it can be forced to report to one area at this address.
If this address is set to 0
option 5 at P124E will apply.
ZONE ALARM CONTACT ID REPORT CODE
ZONE ALARM CONTACT ID REPORT CODE -
P157E 1-64E (3 digit event code)
Normally a zone alarm would default to reporting a standard “Burglar Alarm” code of “130” when the zone activates. If
the zone is not being used as a burglar alarm and you need to identify the correct type of alarm event you can
change the event code at this location (eg if zone 5 was a fire sensor you could program a value of “110” at
P157E5E).
ZONE NEAR ALARM CONTACT ID REPORT CODE
ZONE NEAR ALARM CONTACT ID REPORT CODE -
P158E 1-64E (3 digit event code)
If the Near & Confirmed zone alarm reporting option was active the default report code for a “Near Alarm” is “138”
when the zone activates for the first time. There should be no reason to change this code but if some special event
code was to be used it can be changed at this location.
ZONE CONFIRMED ALARM CONTACT ID REPORT CODE
ZONE CONFIRMED ALARM CONTACT ID REPORT CODE -
P159E 1-64E (3 digit event code)
If the Near & Confirmed zone alarm reporting option was active the default report code for a “Confirmed Alarm” is
“139” when a second zone activates within 45 minutes of the near alarm. There should be no reason to change this
code but if some special event code was to be used it can be changed at this location.
ZONE ALARM VOICE MESSAGE NUMBER
ZONE ALARM VOICE MESSAGE NUMBER -
P160E 1-64E (Value 0-99)
If the reporting format is set to Voice (option 4 on at P182E), the panel will report using the canned voice messages
(eg a zone one activation will report as “Zone 1 Alarm”). The number programmed at this location is reserved for
future use but to ensure the canned messages are reported in Voice mode it MUST be set to at least a value of 1. If
set to a value of 0 the canned messages will not be reported. If Option 1 at P46E is turned on (use near and
confirmed alarm reporting) the panel will not send an alarm in this format.