Page 80 

RUNNER 8/

4

6

 PROGRAM SUMMARY GUIDE

The following program summary is an abbreviated version of all the panel program addresses. This is intended as a 
quick guide to finding a program address. In many address locations, there is a main address (e.g. “

P1E

”), then a sub 

address (e.g. P1E “

1E

”). You must enter in the main address number, followed by the sub address, then you can 

enter the actual data. The program addresses are in numerical order with page references beside them so you can 
get more detailed information if required.

 

This Summary is split into 13 headings. These are; 

1) Users -

Page 80 

7) Zones -

Page 88 

2) Miscellaneous Panel & Clock Settings -   Page 82

8) Time Zones -

Page 91 

3) Outputs -

Page 83 

9) Dialler -

Page 91 

4) Areas -

Page 84 

10) Telephone Numbers -

Page 92 

5) Keypads -

Page 86 

11) SIA Report Codes -

Page 93 

6) Zone Key-Switches -

Page 88 

12) Panel Diagnostic & Default Options -  

Page 93 

13) IP Alarm Set-up -

Page 94

 

+++++Users+++++ 

Programming User Codes 

P1E 

1-2000E  User Code 1-2000 -

Default for User Code # 1 (P1E1E)   = 123   Codes can be  1-6 or 4-6 digits

Page 24 

(where 1E = User Code #1 to 2000E = User Code #2000) 

NOTE: 

The 2000 Users can be keypad Code, Radio or Access key Users. They can be mixed but the Maximum is 2000 Users.

The User type MUST be set to “0” (P2E User# E) for a code to be entered at the above address

.

User Type (Code/Radio/Access Tag-Card) 

P2E 

1-2000E  User # 1-2000 Type - 

  

0 = Keypad Code User {PIN}

Page 24 

(Default = 0)

 

1 = Radio User (Users 101-2000 only) 
2 = Access Tag/Card User 
3 = Both Code and Access Tag/Card User {Tag + PIN) 
4 = Either Code or Access Tag/Card User {Tag or PIN}

User Area Assignment 

P3E 

1-2000E  User # 1-2000 Area -

01-32 = Assigned to Area 1-32

Page 25 

(Default = 1)

 

User Code Access Options

 

P4E 

1-2000E  Users 1-2000 Access Options

1 = Code can Arm Area

Page 25 

(Default = 1,3,4)

2 = Code can arm Stay Mode
3 = Code can Disarm Area
4 = Code can disarm Stay Mode
5 = Code is a Security Guard Code

 

6 = Code will Arm Latchkey Mode
7 = User can reset Latched Egress Outputs
8 = Can View Event Memory 

User Code Privileges

 

P5E 

1-2000E  Users 1-2000 Privileges

1 = User can Change their Code

Page 26 

(Default User 1 = 2,3,4,5,6,7,8)

2 = User can Change All Codes

(Default User 2-2000 = All Off)

3 = User can Allow Access to Installer Mode/Edit all Codes

 

 

4 = User can Change Telephone Numbers
5 = User can Change the Clock

 

6 = User can Change DTMF Command Codes
7 = User can Learn New Radio Devices
8 = Spare 

User Code Miscellaneous Options

 

P6E 

1-2000E  Users 1-2000 Misc Opts

1 = User is Excluded from Global trouble Reset

 

Page 26 

Radio User Type

 

P7E 

101-2000E Radio User 101-2000 Type

0 = General Pendant Type

Page 26 

(Default = 0)

1 = Crow Freewave Pendant
21 = Ness Pendant 

Radio User Privileges

 

P8E 

101-2000E Radio Users 101-2000 Privileges  

1 = Pendant Can Disarm at All Times

 

Page 27 

(Default = 1)

2 = Pendant Causes Immediate Panic
3 = Pendant Causes Delayed Panic ( 1.5 Sec)
4 = Pendant only works during Entry Delay
5 = This User is a Duress Code (Users 21-100)

 

6 = Spare
7 = Spare

 

8 = Spare

Содержание RUNNER 8/64

Страница 1: ...Installation Programming Guide RUNNER 8 64 8 64ZonesControlPanel...

Страница 2: ...ovide you with a new generation of alarm controller The RUNNER 4 8 6 is a de signed and built product which brings you the quality and features which you deserve at an affordable price In addition to...

Страница 3: ...EYPAD MENU OPERATION 19 ACCESSING PROGRAM MODE 22 USERS 24 User Codes 24 User Type 24 User Areas 25 User Arm Disarm options 25 User Program Mode Access 26 Radio User Type Panic options 26 User Time zo...

Страница 4: ...s Zone CID Report Codes 60 Zone Inactivity Timer 61 Learn Find Delete Radio Zone Codes 61 Program LCD Zone Names 62 TIME ZONES 62 Time Zone Days 62 Time Zone Start Stop Times 62 DIALLER 63 Enable Dial...

Страница 5: ...IP Switch 13V8IN TAMP C 0V 12V OUT 0V 12V OUT DAT CLK 0V 12V OUT 1 2 C 3 4 INPUT 5 6 C 7 8 INPUT Zone Expander DAT CLK 0V 12V OUT 0V 12V OUT 13V8IN TAMP C DIP Switch Output Expander NO C NC RELAY 2 NO...

Страница 6: ...one types 12 13 or 14 the associated LED will flash to indicate a tamper condition The zone expander can be powered from the main control panel as shown on the connection diagram on the previ ous page...

Страница 7: ...ED is on that indicates the associated relay is on The output expander can be powered from the main control panel as shown on the connection diagram on the previ ous page or there is an optional plug...

Страница 8: ...nd I F 14 ON off ON ON off Wiegand I F 15 off ON ON ON off Wiegand I F 16 ON ON ON ON off Wiegand I F 17 off off off off ON Wiegand I F 18 ON off off off ON Wiegand I F 19 off ON off off ON Wiegand I...

Страница 9: ...for the reader input Input 1 can be linked to the zone number that matches the keypad address of the board and output 1 is linked to the output number that matches the keypad address Also when DIP swi...

Страница 10: ...01 because it is inside the brackets To select the next area and also see the other areas press the BYPASS but ton to move the display to the right To move back press the button to move back to the l...

Страница 11: ...3 P126E Vibration Mode only supports this EOL value 2k2 Red Red Red Single EOL 4 3k3 Orange Orange Red Single EOL 5 3k9 Orange White Red Single EOL 6 4k7 Yellow Violet Red Single EOL 7 5k6 Green Blue...

Страница 12: ...Monitoring Zone 2k2 4k7 Alarm Contact N C PIR Internal Connections Alarm Tamp Tamp Alarm 0V 12V Tamper Contact N C 0V 12V EXAMPLES OF ZONE WIRING OPTIONS Type 15 Configuration Zone Doubling NO Tamper...

Страница 13: ...rt circuits The accessory outputs are marked 12V and 0V while the keypad buss 12V supply is labelled POS NEG The 12V outputs are supplied by thermal fuses The recommended maximum total load that shoul...

Страница 14: ...l hear the message Area 1 Disarmed If you then press the key it will change the state or Area 1 eg you will hear the message Area 1 Armed DTMF Output Control If for example the DTMF code to remotely c...

Страница 15: ...button to move to the next event If you wish to go back and look at an earlier event you can use the button to go back to an earlier event Each time the Down arrow is pressed the memory will go back...

Страница 16: ...done in Local Program Mode To enter Local Program Mode on the FULL LCD Keypad you must press PROGRAM then BYPASS then ENTER sequential button entry The display will show keypad number and the current...

Страница 17: ...button then within 2 seconds press the 1 button to increase the frequency or press the 2 button to decrease the frequency To move through the different frequencies you have to continue to hold down th...

Страница 18: ...ext Program LCD KP Area Name P69E 1 32E Program LCD KP Area Name Text Program LCD KP Keypad Name P100E 1 32E Program LCD KP Keypad Name Text Program LCD KP Zone Name P169E 1 64E Program LCD KP Zone Na...

Страница 19: ...he top line of the LCD display and the Sub Menus will appear on the bottom line Each press of Up or Down arrow keys will advance the Sub Menus displayed on the bottom line either up or down by one loc...

Страница 20: ...n Menu If you get back to the USERS menu and press the PROG button once more the display will go to the program exit menu If you press ENTER when at this point the panel will leave program mode If you...

Страница 21: ...nt mode see the options at address P5E Each User can have different privileges based on the options assigned to the User at ad dress P5E If no options are set at address P5E for a user they will not b...

Страница 22: ...pattern PROGRAM 1 2 or 3 digit program address ENTER Program Address 1 short beep if OK 1 long beep if error THEN PROGRAM 1 2 3 or 4 digit sub address ENTER Sub Address 3 short beeps if OK 1 long bee...

Страница 23: ...ress the 0 button maintained for compatibility with the current RUNNER operation or you can press and hold the 0 button for 3 seconds to delete the code We recommend using the second option of holding...

Страница 24: ...tored in the panel If the Proximity Reader with the full keypad is installed on the panel it is possible to arm disarm the alarm or gain access through a door by entering in the user code at the reade...

Страница 25: ...option 1 on they can access Client Program Mode and change their code number Option 2 User can Change All Codes If a User has option 2 on they can access Client Program Mode and change All User code n...

Страница 26: ...or longer that 1 5 seconds If the button is released before the time expires no Panic Alarm will be generated Option 4 Pendant only works during entry delay If a Radio Pendant has option 4 on the pend...

Страница 27: ...perating outputs from a particular keypad this is done at locations P82E P83E RADIO PENDANT PANIC BEEPS to KEYPAD RADIO PENDANT PANIC BEEPS to KEYPAD P11E 101 2000E NOTE only Users 101 2000 can be Rad...

Страница 28: ...locations including radio zones before saving the new code to ensure that the code has not already been loaded into another slot If the code already exists the keypad will indicate which slot the cod...

Страница 29: ...r Card is stored a number from 1 2000 The keypad will stop beeping once the memory location has been found Manually enter in a Card Tag Printed Number P24E 1 2000E Enter in the 10 digit printed card t...

Страница 30: ...rm DIAL REPORT DELAY DIAL REPORT DELAY P25E 3E 0 255 Seconds If this address is set to 0 there will be no report delay If it is set to any value other than 0 then a delay equal to the programmed value...

Страница 31: ...2k2 resistor EOL across the Tmp 0V terminals to ensure the tamper is sealed If this option is turned off then a simple short circuit is all that is required to seal the panel tamper Option 2 Direct a...

Страница 32: ...cannot be re armed until the Installer has reset the alarm The Installer must access Installer Program Mode via Client Mode to reset the system The Trouble indication will latch on even if the tamper...

Страница 33: ...s assigned P3E to the user code is are armed If the user code is assigned to area 1 but area 2 was armed the code can still operate the output If no areas are assigned at P3E this option has no effect...

Страница 34: ...s can be armed If this option is turned on it is possible to arm an area while the panel is in program mode provided each keypad is in a different area eg if KP 1 was in area 1 and KP 2 was in area 2...

Страница 35: ...y the panel eg this timer expires the panel will send Bye SETTING REAL TIME CLOCK REAL TIME CLOCK HOUR MINUTE P26E 1E Value 0 2359 REAL TIME CLOCK DAY of WEEK P26E 2E Value 1 7 where 1 Sunday 2 Monday...

Страница 36: ...his is useful for things like 24 hour smoke alarms which can sound at a lower volume when disarmed but sound at full volume when armed Also if a day zone triggers output 1 or 2 the output will produce...

Страница 37: ...n a Mains Fail alarm to an Output Option 2 Fuse Failure to Output This option is used to assign a Fuse Failure alarm to an Output The on board fuses are thermally activated If excessive current is dra...

Страница 38: ...IONS D P37E 01 32E Option 1 Siren Driver to Output applies to O P 1 2 only requires an 8 speaker Option 2 Output Chime Timer is in Minutes Option 3 Output Silenced for 10 seconds on key press Option 4...

Страница 39: ...must be set to a minimum value of 10 for the reader LED to display the chirps OUTPUT RESET TIME OUTPUT RESET TIME P40E 01 32E 0 65535 Seconds 0 latched output The Reset time affects the time the outp...

Страница 40: ...e directly To enter Bypass mode the User must press BYPASS CODE ENTER before they can bypass zones Option 5 Spare Option 6 Report Arm Signal at the end of the Exit Delay If this option is on the panel...

Страница 41: ...endant chirps programming P50E P53E to Arming or Disarming via the Access Tag or Card If this option is On the chirps will apply to Access Tag Cards If the chirps are required to be displayed at the r...

Страница 42: ...horn speaker is connected to the output see P37E1 or 2E option 1 the siren on the output will give a single tone for the chirp instead of the swept tone used for alarms Also Stay Arming via an Access...

Страница 43: ...rea is Armed it is useful to have the exit delay beeps occurring at the keypad to warn the User to exit the premises without delay If the option is on at this address that keypad will beep out the exi...

Страница 44: ...ART OF DTMF ARM DISARM STATUS MESSAGES P64E 1 32E 1 Area 1 32 Area 32 0 99 Reserved for future use ARMED EXIT BEEPS to OUTPUT ARMED EXIT BEEPS to OUTPUT P65E 1 32E 1 Area 1 32 Area 32 Value 01 32 for...

Страница 45: ...a will turn on when the Time zone ends eg 1700 and turn off when a Time zone starts eg 0830 Program LCD KP Area Name Program LCD KP Area Name Text P69E 1 32E Each Area can have a custom name that will...

Страница 46: ...ton on a keypad If you press the CHIME button on a keypad for 2 seconds and this option is turned on for that keypad the display will show NOCH on the ICON LCD or Chime Mode OFF on the FULL LCD keypad...

Страница 47: ...g option 4 at P72E the stay arming can be disabled at any of the 32 keypads At this address the disarming of stay mode can be disabled Between P72E option 4 and this program option a stay arm only and...

Страница 48: ...signed to only Area 1 it can only Arm or Disarm that area Option 32 Area 32 This option assigns the keypad ARM button to Area 32 If a keypad ARM button is assigned to only Area 32 it can only Arm or D...

Страница 49: ...work options 2 3 must be off at location P45E Option 2 STAY button can Arm Stay Mode This option enables single button Arming of Stay Mode using the STAY button For single button operation to work op...

Страница 50: ...A button can Disarm Stay Mode at All Times This option enables single button Disarming of Stay Mode using the A button For single button disarm operation to work options 2 3 must be off at location P...

Страница 51: ...e button Arm operation to work options 2 3 must be off at location P45E When Latchkey Mode is set on Arming any code without the Latchkey option P4E Option 6 used to Disarm the Alarm will cause a Disa...

Страница 52: ...KEYPAD DURESS ALARM to OUTPUT P87E 1 32E Value 01 32 for Outputs 1 32 Option 01 Output 1 Option 32 Output 32 A Keypad generated Duress Alarm see P25E2E can be assigned to an Output or multiple Output...

Страница 53: ...not beep the keypad buzzer The Keypad Chime Timer can be set to a value from 1 255 The units are in 1 10th second increments This means that a value of 10 will beep the keypad buzzer for 1 second LCD...

Страница 54: ...1 Option 32 Proximity Reader LED follows Output 32 If a proximity reader is connected to the control panel via the Wiegand Interface it may be desirable to have the LED provide some form of indicatio...

Страница 55: ...igned has option 5 on they can Arm all Areas assigned but they may only Disarm if the panel is currently Armed and in the alarm state Option 6 Key Switch will Arm Latchkey Mode If the panel is armed b...

Страница 56: ...Exit Delay Zone If this option is turned on the zone will not have any exit delay and will cause an instant alarm if triggered during the exit delay time Also you MUST ensure that if this option is tu...

Страница 57: ...eset zone is activated during the armed state but then resets before the entry delay expires no alarm will be generated Once an alarm has been generated with an Auto reset zone the alarm will be remov...

Страница 58: ...d of no alarms it can be re instated as part of the alarm by removing the Soak Test option Option 5 Report using the highest assigned Area If a zone is assigned to more than one area and it is program...

Страница 59: ...le zone with tamper Option 6 4k7 Option 7 5k6 ZONE RESPONSE TIME There are 8 hardwired zone inputs on the panel plus up to 64 zones via the zone input expanders The response time how quickly the input...

Страница 60: ...a supervised alarm is generated Type 3 Freewave with checksum supervised signal active If a Crow Freewave radio PIR is used selecting Type 3 will allow the panel to correctly recognize the alarm tamp...

Страница 61: ...alue 01 32 for Outputs 1 32 Option 01 Output 1 Option 32 Output 32 If a zone is programmed as a 24 Hour type and it activates the zone can trigger selected Outputs for local alarm signalling If the zo...

Страница 62: ...P139E 1 64E Value 01 32 for Keypads 1 32 Option 01 Keypad 1 Option 32 Keypad 32 If a hardwired zone is programmed to allow tamper monitoring P125E types 12 13 14 or the zone is a radio detector with...

Страница 63: ...o reporting a standard Burglar Alarm code of 130 when the zone activates If the zone is not being used as a burglar alarm and you need to identify the correct type of alarm event you can change the ev...

Страница 64: ...rted and the LED on the receiver will flash Now operate the detector you wish to learn into Zone 5 slot Once the transmitted code has been received by the panel and saved the keypad will stop beeping...

Страница 65: ...off a Door Forced alarm will be created If the output is on and the door opened but the door is still open when the output resets a Door left open too long alarm will be created If the panel is set u...

Страница 66: ...will auto reset when the input seals ACCESS DOOR FORCED OPEN BEEP to KEYPADS Access Door Forced Open Beeps to Keypads P6178E 1 64E Value 01 32 for Keypads 1 32 If a zone set as an Access Door Monitor...

Страница 67: ...ishes It would normally be set to the end of the day eg if you were automatically arming and disarming an area with a time zone and you wanted it to arm when the time zone ended you would set the end...

Страница 68: ...Option 2 Spare Option 3 Spare Option 4 Send Test Calls Only if Armed Option 5 Test Time Period is in days Option 6 Hold line open following Domestic Voice report for DTMF control Option 7 Ring Timeou...

Страница 69: ...Listen in Enabled through the entire call only in Armed State Option 6 Listen in Enabled through the entire call only in Monitor Mode Option 7 Listen in Enabled when the panel answers a call Option 8...

Страница 70: ...t number you wish to control eg 01 for Output 1 followed by the key The current status of the output will be given After that if you press the button on the telephone the status of the output will tog...

Страница 71: ...E 11E Value 0 99 The panel has default canned messages that are used to annunciate the above alarm events The Voice Message number is reserved for future use but to ensure that the canned messages are...

Страница 72: ...t ri01 or ri02 but it will also send different account codes if programmed that way To avoid using two account numbers when reporting alarms on different areas you should program all account codes P62...

Страница 73: ...ES per TELEPHONE NUMBER MAXIMUM DIAL RE TRIES per TELEPHONE NUMBER P184E 1 8E Value 0 99 The maximum dial re tries is the number of times that the panel will dial a telephone number in an attempt to g...

Страница 74: ...Arm Disarm If this option is on then all Arm Disarm signals will be reported to a Monitoring Station if Contact ID or 4 2 is set as the reporting format Option 2 Report Stay Mode Arm Disarm If this o...

Страница 75: ...test calls will be sent but if test calls are not required they can be disabled by turning this option off Option 4 Report Fuse Failure The panel has two on board thermal fuses designed to protect th...

Страница 76: ...P196E 1 64E Value from 1 14 taken from the chart above PANIC ALARM SIA REPORTING CODES PANIC ALARM SIA REPORTING CODE P197E 1E Value from 1 14 taken from the chart above FIRE ALARM SIA REPORTING CODE...

Страница 77: ...ogram mode The results of the walk test will be saved in the memory event buffer and can be viewed by accessing memory display mode to verify which detectors were triggered during walk test mode If Ou...

Страница 78: ...ion 1 DHCP or Manual Panel IP address Off Automatic DHCP On Manual IP setting Option 2 Enable logging of Ethernet resets Option 3 Sync panel clock to the internet time Option 4 Enable Serial over IP C...

Страница 79: ...8 8 4 4 PRIMARY TIME SERVER P201E 11E If the panel is permanently connected to the internet the panel clock can be synced to an internet time server The primary time server can be programmed at this l...

Страница 80: ...ype 0 Keypad Code User PIN Page 24 Default 0 1 Radio User Users 101 2000 only 2 Access Tag Card User 3 Both Code and Access Tag Card User Tag PIN 4 Either Code or Access Tag Card User Tag or PIN User...

Страница 81: ...ad 01 A Radio panic will Beep at Keypad 1 Page 28 Default All On 02 A Radio panic will Beep at Keypad 2 03 A Radio panic will Beep at Keypad 3 04 A Radio panic will Beep at Keypad 4 05 A Radio panic w...

Страница 82: ...ly enter in a Card Tag Printed Number P24E 1 2000E Enter this address then type in the 10 digit printed card tag number Page 30 Code Tag Radio User Usage Count P1025E 1 2000E A value of 1 254 equals t...

Страница 83: ...rming method 7 Enable Keypad Tamper Switch Alarms 8 Spare LCD KP Idle Display Name P25E 14E This location is where the LCD KP Idle Display Name can be Programmed Page 34 Webpage Incorrect Login Count...

Страница 84: ...ll Off 3 Battery Low to output 4 Telephone Line Failure to Output 5 Supervised Radio Signal Failure 6 Sensor Watch Alarm 7 System Tamper to Output 8 Receiver Fail Programming Output Options C P36E 1 3...

Страница 85: ...t All Off NOTE If an Area Disarm has turned an Output ON this will override any reset time programmed for the Output The reset pulse or chime timers can resume controlling the Output once the Area is...

Страница 86: ...ff Page 44 Default 0 for all Areas Area 1 32 Auto Arm Disarm Time zones P68E 1 32E Area 1 32 Auto Arm Disarm Time zones Value 01 32 for Time zones 1 32 Page 44 Default All Off Program LCD KP Area Name...

Страница 87: ...5 2 4 3 STAY Button can Disarm at All Times 4 STAY Button can Disarm Stay Mode at All Times 5 STAY Button can Reset Alarms 6 STAY Button can Arm Latchkey Mode 7 STAY Button can Disarm During Exit Dela...

Страница 88: ...will Beep KP 1 32 Manually Operated Medical Alarm Beeps to Keypads P92E 1 32E Medical Alarm Beeps to Keypads Page 51 Default All On 01 32 A Medical Alarm at the selected keypad will Beep KP 1 32 Wrong...

Страница 89: ...C Default Zone 5 8 1 7 8 3 Not an Exit Delay Zone Default Zone 9 16 7 8 4 Keypad Zone 5 Zone is a Radio Zone 6 Zone is a Stay Mode Zone 7 Zone can be Manually Bypassed 8 Zone can be Auto Bypassed Pro...

Страница 90: ...64E Chime Zone Alarms to OutputPage 59 Default All Off 01 32 A Chime Zone Alarm will Turn On Output 1 32 Zone Tamper Alarms to Outputs P132E 1 64E Zone Tamper Alarms to Output Page 59 Default 1 2 01...

Страница 91: ...fault 1 Page 61 Away Zone Entry Delay to Outputs P161E 1 64E Away Zone Entry Delay to Outputs Page 62 Default All Off 01 32 Armed Zone Entry Delay to output 1 32 Stay Mode Entry Delay to Outputs P162E...

Страница 92: ...Zones 1 32 Days Page 63 Default All Off 1 Sunday 2 Monday 3 Tuesday 4 Wednesday 5 Thursday 6 Friday 7 Saturday 8 Invert Programming Time Zone Start End Times P172E 1 32E Time Zones 1 32 Start Time Va...

Страница 93: ...edge Code P175E 14E Voice Domestic Acknowledge Code Value 1 4 digit code 1 9999 Default 0 Page 67 Force Test Call Code P175E 15E Force Test Call Code Value 1 4 digit code 1 9999 Default 0 Feature disa...

Страница 94: ...rt Disarm only after an Activation 4 Report Stay Mode Disarm only after an Activation 5 Report Stay Mode Zone Alarms 6 Report Access to Program Mode 7 Report 24 Hour Alarms when set to Domestic Voice...

Страница 95: ...200E 12E Default ALL LCD text Page 74 Read RSSI from Pendants and Wireless Zones P200E 14E Read RSSI from Pendants and Wireless Zones Page 74 IP Alarm Setup Panel IP Address P201E 1E Control Panel IP...

Страница 96: ...13E Serial over IP Port Default 9000 Page 77 IP Reporting Poll Timer P202E 1 8E IP Reporting Poll Timer 0 9999 minutes Page 77 Monitoring IP Reporting Number URL P203E 1 8E Monitoring IP Reporting Nu...

Страница 97: ...disarm all areas If before pressing the enter button you wish to deselect one or a number of the allowed areas before disarming you can enter the two digit area numbers corresponding to the areas you...

Страница 98: ...telephone number The formats are listed on page 108 ACCOUNT CODE P62E 1 32E Area 1 Account code is P62E1E and Area 2 Account code is P62E2E up to P62E32E for Area 32 Account code Alternatively only A...

Страница 99: ...E12E User options hide user codes to installer X P26E all Time Date and Daylight Savings X P170E Change Holidays X P63E Area A B Command Code X P164E Learn radio zone X P165E Delete radio zone X P166E...

Страница 100: ...e disconnected before the power is disconnected Similarly when reconnecting the dialler it is necessary to power up the panel before connecting the dialler to the Telecom Network Connection to the Tel...

Страница 101: ...9 001 to 064 Zone Key switch 1 64 Arm Disarm Arm Disarm by DTMF or Up Download 407 000 Remote Arm Disarm Arm by Security Interlock Zone 407 001 to 064 Arm by Security Interlock zone 1 64 Arm Disarm by...

Страница 102: ...rebooted RF Receiver jam detected 344 000 RF Jamming Detected Dialler Failure 354 000 Failure to get kiss off IP Failure 356 000 Failure to send IP Poll Access Door Forced Alarm 423 001 to 032 The acc...

Страница 103: ...H Panel Keypad or Wiegand IF 2 Tamper Switch Activated TA TR Zone Expander Tamper Activated ES EJ Output Expander Tamper Activated TT TJ Zone Output or Wiegand IF 2 fail EM EN Battery Low see CID for...

Страница 104: ...SJ Water 10 WA WH WB WU WT WJ Heat 11 KA KH KB KU KT KJ Freeze 12 ZA ZH ZB ZU ZT ZJ Equipment 13 IA IR CHART FOR THE PROGRAMMABLE SIA EVENT CODES Equip Tamper 14 TA TH TB TU TT TJ When you program on...

Страница 105: ...99 functions work the same during disarm V225 Date 08 11 2016 At software version V225 an Arm on No Activity option was added There are two ways to achieve that 1 The area can be assigned a time zone...

Страница 106: ...the reset time is not affected by this option any longer V242 Date 15 02 2017 There was a bug if using Patriot IP format P82E option 6 The restore events were being sent as a new event This was fixed...

Страница 107: ...ful if there is a land based internet that could be subject to service interruption a secondary cellular gateway could serve as a back up 3 A primary and secondary DNS server address has been added P2...

Страница 108: ...output will remain on once triggered There are two ways to reset this state The first is the output will turn off as soon as the input is sealed again provided option 3 is turned on at the new progra...

Страница 109: ...s to allow for longer output timing V271 Date 04 08 2017 If the panel is restarted following a firmware or configuration update and outputs were supposed to be turned on by a schedule they would not c...

Страница 110: ...port Tel Fax sales crow co il support crow co il www thecrowgroup com These issues 2018 March to prior circulation in previous all supersede instructions 9726001 3 972 9726000 3 972 Israel 70100 City...

Отзывы: