Page 75
DIALLER REPORTING OPTIONS “D”
DIALLER REPORTING OPTIONS “D” -
P189E 1-8E
Option 1 - Report Latchkey Disarm
Option 2 - Report Delinquency Alarm
Option 3 - Report Test Calls
Option 4 - Report Fuse Failure
Option 5 - Report Output 1 or 2 Fail
Option 6 - Report RTC (Real Time Clock) Time changed
Option 7 - Report Keypad Buss Trouble
Option 8 - Report RF Interference (Jamming) Detected
Option 1
Report Latchkey Disarm -
If the panel is armed in Latchkey Report Mode by using a Code, Key-switch,
<ARM>, <STAY>, <A> or <B> buttons, any code or key-switch without the Latchkey option (P4E or
P112E Option 6 off) used to Disarm the Alarm will cause a Latchkey Disarm report to be sent via the
dialler. For Domestic or Voice reporting option 1 at P188E must also be turned ON.
Option 2
Report Delinquency Alarm -
If the panel has been configured for Delinquency monitoring (P67E) and
an area has not been armed for the time set at P67E, a Delinquency Alarm will be sent to the Monitoring
Station if Contact ID or 4 + 2 is set as the reporting format.
Option 3
Send Test Calls
- If Contact ID format is used for reporting alarm, the panel can also send Automatic
test calls. If this option is turned on the test calls will be sent but if test calls are not required they can be
disabled by turning this option off.
Option 4
Report Fuse Failure -
The panel has two on-board thermal fuses designed to protect the 12v DC
outputs from short circuits. If this option is on and either of these fuses are open, a report will be sent to
the monitoring station if Contact ID is set as the reporting format.
Option 5
Report Output 1 or 2 Fail -
The panel has two high current Outputs (O/P 1 & 2). These Outputs are
normally used to drive sirens or strobes for local alarm warning. If option 8 at location P37E is on for
either O/P 1 or 2 the Output status will be monitored (eg wire to siren has been cut). If this option is on
and a fault is detected on the output, a report will be sent to the monitoring station if Contact ID is set as
the reporting format
Option 6
Report RTC (Real Time Clock) Time Changed -
If the panel clock is changed and this option is turned
on, the event will be reported to the monitoring station.
Option 7
Report Keypad Buss Trouble -
If any connected keypads are removed from the system they will be
reported as missing if this option is turned on.
Option 8
Report RF Interference (Jamming) Detected -
If the radio receiver detects RF Interference (jamming)
of the radio frequency the panel can report this event to the monitoring station if this option is turned on.