HT-OMSMART-A
46
• Remove the outer filter bowl, and then remove the
filter and thoroughly clean it before re-assembly.
• Make sure the valve, at the bottom of the filter, is
closed before operation.
FILLING THE SPRAYER
Use clean freshwater, free of suspended organic matter
or clay as some chemicals are de-activated when they
contact these materials. Ensure sufficient water quantity to
allow correct product blending.
Main Tank
When filling the main tank (freshwater only), open the
spray tank lid and fill the tank with the basket filter in place.
Clean the basket and replace the lid after filling.
Or …
Fill via the separate camlock quick fill (freshwater or
chemical premix). Connect to the water source before
opening the ball valve. Shown here in the off position.
Flushing Tank
Use FRESHWATER ONLY (preferably rainwater) in the
flushing tank. Unscrew the lid and fill before spraying.
Replace the lid after filling. 2000L model shown
(next page).
Hand-wash Tank
Fill the hand-wash tank with FRESHWATER ONLY from
a source remote to any chemical source. Replace the lid
after filling.
Always maintain the correct caution label at the fill point.
For more information on the tank positions
across the range see Section 4, pages 21-22
SETTING SPRAYER PRESSURE
The regulator will need to be adjusted from time to time –
early season with low spray application rates versus peak
season with higher spray rates will require this regulator to
be adjusted (see Set-up on
page 41).
WARNING; To set and forget at a high pressure will put
undue stress / wear and tear on the system. Maximum
pressure is 12 bar but 5-8 bar is recommended.
SECTION 6
SPRAY OPERATIONS