RELAY CONNECTIONS
Superterm CIC1800 / CICP1400UL
34
REMOTE Power Mode
In REMOTE power mode, each door strike
operates from an individual power supply
(typically a transformer mounted at the door site).
In the REMOTE power mode, the door strike
relays operate as conventional dry contacts and
may be configured as Normally Open (NO) or
Normally Closed (NC).
NOTES:
Door strike relays operating in the
REMOTE mode do not respond to an emergency
sensor.
Operating a door strike relay in the REMOTE
mode requires setting two jumpers per relay. Refer
to page 72 for specific information about setting
the door strike jumpers.
Door Strike Relay Connection - Normally
Open
Table 20 lists the connections between the RLY#x
terminal strip and the door strike for a Normally
Open (NO) relay condition (see Figure 21).
Table 20 - Connection Table for Door Strike
Relay -
Normally Open (NO) Condition
Door Strike Signal
RLY#x
Positive (+)
Pin 1
Common (-)
Pin 2
NOTE: Operating door strike relays on REMOTE
power requires setting two jumpers per relay.
Refer to page 72, Door Strike Jumper Settings, for
specific information about setting the jumpers.
Door Strike Relay Connection - Normally
Closed
Table 21 lists the connections between the RLY#x
terminal strip and the door strike for a Normally
Closed (NC) relay condition (see Figure 22).
Table 21 - Connection Table for Door Strike
Relay -
Normally Closed (NC) Condition
Door Strike Signal
RLY#x
Positive (+)
Pin 3
Common (-)
Pin 2
NOTE: Operating door strike relays on REMOTE
power requires setting two jumpers per relay.
Refer to page 72, Door Strike Jumper Settings, for
specific information about setting the jumpers.
Auxiliary Relay Connection
The Superterm supports eight auxiliary relays for
controlling external devices including, door alarm
shunts, cameras, temperature controls, intercoms,
area lighting or any other device using electrical
inputs to change the status of a control circuit.
Auxiliary devices only connect to even-numbered
Superterm relays. The eight relays are located on
the bottom center of the Superterm circuit board
above the door strike relays.
The eight auxiliary relays are labeled: RLY 2;
RLY 4; RLY 6; RLY 8; RLY 10; RLY 12; RLY
14; RLY 16.
Auxiliary Relay Power Requirements
The Superterm does not provide on-board power to
the eight auxiliary relays. Each auxiliary relay may
be used to switch an external signal.
Auxiliary Relay Connection - Normally
Open (NO)
Table 22 lists the connections for an Auxiliary
relay in a normally open configuration.
Table 22 - Connection Table for Auxiliary Relay
- Normally Open (NO) Condition
Signal RLY#x
Normally Open
Pin 1
Common Pin
2
Aux Relay Connection - Normally Closed
(NC)
Table 23 lists the connections for an Auxiliary
relay in a normally closed configuration.
Table 23 - Connection Table for Auxiliary Relay
- Normally Closed (NC) Condition
Signal RLY#x
Normally Closed
Pin 3
Common Pin
2
Содержание SUPERTERM CIC1800
Страница 27: ...Figure 15 Superterm Circuit Board Relay Location...
Страница 29: ...RELAY CONNECTIONS Superterm CIC1800 CICP1400UL 29 Figure 16 LOCAL and REMOTE Power Configurations...
Страница 53: ...Figure 34 COM1 Terminal Strip Connection...
Страница 55: ...Figure 35 Connecting Auxiliary RS 232 and RS 485 Devices to the Superterm...
Страница 57: ...Figure 36 Expansion Input Output Board Layout in Superterm Cabinet...
Страница 63: ...Figure 41 DI DO Board Layout Figure 42 DI DO Board to Superterm Power Connection...
Страница 65: ...Figure 43 DI DO Board Alarm Input Terminal Strip...
Страница 67: ...Figure 45 DI DO Board Relay Output Connections and Address Setting...
Страница 73: ...SETTINGS Superterm CIC1800 CICP1400UL 73 Figure 46 232 1 EOL1 and EOL2 Jumper Locations and Settings...
Страница 75: ...Figure 47 COM1 COM2 and MONITOR Jumper Locations and Settings...
Страница 77: ...Figure 48 Jumper Locations and Settings...
Страница 79: ...SETTINGS Superterm CIC1800 CICP1400UL 79 Figure 49 Superterm Door Strike Jumper Settings...
Страница 83: ...Figure 53 256K Memory Upgrade Installation...
Страница 85: ...UPGRADING Superterm CIC1800 CICP1400UL 85 Figure 55 2MB Expansion Board Installation...