RELAY CONNECTIONS
Superterm CIC1800 / CICP1400UL
32
LOCAL Power Door Strike Connection
All door strike relays operating in LOCAL power
mode distribute strike power from the LOCAL
power supply. However, each relay may be
configured in one of two specific ways.
1)
A door strike relay set in a Normally Closed
(NC) configuration holds a door strike circuit
closed until an event triggers the relay and
releases the door strike.
2)
A door strike relay set in a Normally Open
(NO) configuration keeps a door strike circuit
open until an event triggers the relay and
engages the door strike.
NOTE:
Operating the door strike relays with an
emergency sensor requires Normally Closed (NC)
conditions (power is disconnected from the door
strike in emergency situations).
Door Strike Relay Connection - Normally
Open
Table 18 lists the connections between the RLY#x
terminal strip and the associated door strike for a
Normally Open (NO) condition (see Figure 19).
Table 18 - Connection Table for Door Strike
Relay -
Normally Open (NO) Condition
Door Strike Signal
RLY#x Pin
Positive (+)
Pin 1
Common (-)
Pin 2
NOTE:
Operating door strike relays on LOCAL
power requires setting two jumpers per relay.
Refer to page 72, Door Strike Jumper Settings, for
specific information about setting the jumpers.
Door Strike Relay Connection - Normally
Closed
Table 19 lists the connections between the RLY#x
terminal strip and the associated door strike for a
Normally Closed (NC) condition (see Figure 20).
Table 19 - Connection Table for Door Strike
Relay -
Normally Closed (NC) Condition
Door Strike Signal
RLY#x Pin
Positive (+)
Pin 3
Common (-)
Pin 2
NOTE:
Operating door strike relays on LOCAL
power requires setting two jumpers per relay.
Refer to page 72, Door Strike Jumper Settings, for
specific information about setting the jumpers.
Содержание SUPERTERM CIC1800
Страница 27: ...Figure 15 Superterm Circuit Board Relay Location...
Страница 29: ...RELAY CONNECTIONS Superterm CIC1800 CICP1400UL 29 Figure 16 LOCAL and REMOTE Power Configurations...
Страница 53: ...Figure 34 COM1 Terminal Strip Connection...
Страница 55: ...Figure 35 Connecting Auxiliary RS 232 and RS 485 Devices to the Superterm...
Страница 57: ...Figure 36 Expansion Input Output Board Layout in Superterm Cabinet...
Страница 63: ...Figure 41 DI DO Board Layout Figure 42 DI DO Board to Superterm Power Connection...
Страница 65: ...Figure 43 DI DO Board Alarm Input Terminal Strip...
Страница 67: ...Figure 45 DI DO Board Relay Output Connections and Address Setting...
Страница 73: ...SETTINGS Superterm CIC1800 CICP1400UL 73 Figure 46 232 1 EOL1 and EOL2 Jumper Locations and Settings...
Страница 75: ...Figure 47 COM1 COM2 and MONITOR Jumper Locations and Settings...
Страница 77: ...Figure 48 Jumper Locations and Settings...
Страница 79: ...SETTINGS Superterm CIC1800 CICP1400UL 79 Figure 49 Superterm Door Strike Jumper Settings...
Страница 83: ...Figure 53 256K Memory Upgrade Installation...
Страница 85: ...UPGRADING Superterm CIC1800 CICP1400UL 85 Figure 55 2MB Expansion Board Installation...