TDMA CONTROL 602-702 Eng Nov.doc
19
Yield Measurement: Allocation Input-Function-Output
Input
Function
Yield Sensor Flow (Solar Hot)
(Art. Nr. RE 046)
Temperature differential for Yield
calculation
Yield Sensor Return (Solar Cold)
(Art. Nr. RE 046)
Temperature differential for Yieldn
calculation
Flow Meter (Art. Nr. RE 096)
Flow measurement
No Output
5.5.1
Radiation Measurment (Input Data)
Radiation Sensor:
100...1500 W/Vm
2
Here the solar radiation is measured. This requires a radiation sensor to be
connected.
In this menu option, the proportionality factor between the measured volatage
and the solar radiation can be set. The value of the Radiaition Sensor is 100
W/ Vm
2
(RE354) and is preset in the controller.
Solar Radiation: Allocation input - Function - output
Input
Function
Radiation Sensor
(Art. Nr. RE 354)
Measurement of Solar Radiation
No Output
5.5.2
Heat Meter
For the CONTROL 602 select function 3 and 4 (Variant A) and 5 and 6
(Variant B) to activate the calculation of heat quality. The heat meter with
pulse output (No. RE064) is connected to the digital inputs D1 and D2. The
measured amount of energy can then be read directly on the controller in
‘Calc Values’. The CONTROL 702 can have three heat meters, which can be
activated in Select Function 9, 10 & 11.
Heat Meter Pulse Rate D1
Rate 1,0 kwh / pulse
Here the pulse rate of the heat meter can be set. Wioth each pulse recorded,
the appropriate amount of heat is displayed on the controller. The rate is
stated in the manufacturer’s literature for the heat meter.
Heat Meter D 1
To Set?
In this menu item you can enter the details of the heat meter to be used.
Heat Meter D 1
With the and
,
the name / type of meter can be entered with numbers or
letters. The curor than jumps automatically to the next character. When the
name is entered and confirmed with the you can the use the to input
details of other heat meters if fitted.