Ruckus ICX 7750 Switch Hardware Installation Guide
Part Number: 53-1003900-10
Installing the Ruckus ICX 7750
Installing the device in a rack
Installing the device in a rack
NOTE
You need a #2 Phillips screwdriver for installation.
Before mounting the switch in a rack, pay particular attention to the following factors:
•
Temperature: Because the temperature within a rack assembly may be higher than the ambient room temperature, check that
the rack-environment temperature is within the specified operating temperature range. (Refer to
“Environmental considerations”
•
Mechanical loading: Do not place any equipment on top of a rack-mounted unit.
•
Circuit overloading: Be sure that the supply circuit to the rack assembly is not overloaded.
•
Grounding: Rack-mounted equipment should be properly grounded. Particular attention should be given to supply connections
other than direct connections to the mains electricity supply.
To mount the product into a four-post rack, you can order a four-post rack kit with the part number XBR-R000295. For the procedure to
install this kit, refer to
“Installing the 1U, 1.5U, and 2U Universal Kit for Four-Post Racks (XBR-R000295)”
Two-post rack mount installation
The Ruckus ICX 7750 can be installed in a two-post rack in various mounting positions, as shown in
.
FIGURE 11
Two-post rack mounting positions
DANGER
Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over.
1
Front flush mount
4
Reverse mid-mount
2
Reverse-front mount
5
Rear mount
3
Front mid-mount
6
2-post rack, side view