Station Dimensions–continued
Scout 900
MX
Base Unit
Handset
Footprint (inches)
7.30 X 5.12
8.15 X 2.19 X 1.85 with belt clip
Weight (ounces)
16 oz less AC adapter
8.5 oz with battery and belt clip
Conferencing
Maximum Combinations
at Any One Time
J0408 and J0816
J1632
1 five-way plus 1 three-way plus 2
SOHVA
4 five-way plus 1 three-way plus 1
SOHVA
2 four-way plus 2 SOHVA
6 four-way plus 2 three-way
1 four-way plus 3 three-way
3 four-way plus 9 three-way
5 three-way plus 1 SOHVA
16 three-way
SMDA Storage Capacity
J0408
J0816
J1632
800
1600
1600
Station Cable Requirements
Type
2-wire (1-pair) twisted, non-shielded cable
Maximum Length
1000 feet with 24 gauge wire, 2000 feet with 22 gauge wire
Switching Principle
Digital, time division multiplexing (TDM). Provides non-blocking switching with stored
program control
Operating Environment
Temperature
32-122 degrees F (0-50 degrees C)
Humidity
90 percent relative, non-condensing
Power Requirements
J0408
J0816
J1632
JM408 and
JM008
Voltage
90-129 VAC Single phase all models
Current
0.6A
2.0 A
2.1A
Not Applicable
Power
70W
135W
150W
Not Applicable
Volt/Amps
80VA
190VA
200VA
Not Applicable
Terminations
Station
Standard 50-pin male connectors for connection to external distribution field
Line
Standard 6-conductor mini-jack (USOC 14C)
IMI66–132
DSU II Digital Telephone System
1–22 Introducing The DSU II Digital Telephone System
Содержание DSU II