Always pull out the mains plug when not using the machine, before changing the 

mixing tool or before star琀椀ng any maintenance work. 

•  Never use the cable to pull the plug out of the socket outlet. Protect the cable from 

heat, oil and sharp edges. 

•  For outdoor use, use only cables which have been approved for the purpose and bear 

corresponding markings. 

•  Never connect the machine to household socket outlets. It may only be connected to 

special power outlets, e.g. distribu琀椀on boards for construc琀椀on sites with earth-leakage 

circuit-breakers. 

•  If a cable reel is used, the cable must be fully unwound. There is a risk of the cable 

catching  昀椀re  from  overhea琀椀ng.  It  can  also  cause  a  loss  of  power  which  will  in  turn 

trigger the undervoltage fuse. 

•  Before you switch on the machine, check that the tool wrench and any other objects 

have all been removed from the mixing tub. 

•  Never mix any materials with a 昀氀ash point of below 70°F (21°C). Never use any solvents 

with a 昀氀ash point of below 70°F (21°C) to clean the machine. Risk of explosion! Never 

use the machine in any areas where there is a poten琀椀ally explosive atmosphere. Risk of 

explosion! 

•  Always  make  sure  the  machine  is  at  a  stands琀椀ll  before  you  ever  take  any  material 

samples. 

• 

Do not operate the machine without the guard cage or without any of the parts of the 

housing. Risk of crushing! 

• 

The consequence of deliberately shu琀�ng o昀昀 any of the safety func琀椀ons is an acute 

risk of accidents and injury. 

•  Never use the trolley for any other purpose than for transpor琀椀ng the original Collomix 

mixing tub for which it is designed. 

•  Only open and close the machine with the handle provided. There is a risk of crushing 

if you a琀琀empt to open and close it at any other point. 

•  Always replace the gas-pressurized spring with a new one if it is defec琀椀ve. Never open 

the gas-pressurized spring as it is pressurized. Risk of injury! 

•  Make sure that the control pin moves without hindrance at all 琀椀mes and that the limit 

switch also works properly at all 琀椀mes. It is impera琀椀ve that these never become soiled. 

A  malfunc琀椀on  here  may  cause  the  mixing  tools  to  start  up  uninten琀椀onally.  Risk  of 

crushing! 

•  If the machine is li昀琀ed by a crane or similar, the li昀琀ing ropes/cables or belts must only 

be fastened to the described points provided on the machine. Never stand under the 

suspended load. 

•  Use only original replacement parts. 

 3.1  Responsibility of the user

These Opera琀椀ng Instruc琀椀ons must be kept in close proximity to the machine and must be 

available to all persons working with or on the machine at all 琀椀mes. 
Never use the machine if it is not in good working order or is not safe to use. Check that the 

machine is in proper working order every 琀椀me before you start using it.

Содержание XM 2-650

Страница 1: ...ev US02 2013 Page 1 Operating Instructions FORCED ACTION MIXER FORCED ACTION MIXER COLLOMATIC XM 2 650 COLLOMATIC XM 2 650 110 VAC 60 hz US Collomix GmbH Daimlerstra e 9 85080 Gaimersheim Germany Tele...

Страница 2: ...Forced action mixer Collomix GmbH Collomatic XM Gaimersheim Germany Page 2 Rev US02 2013 Ref no 39017...

Страница 3: ...6 Disposal 9 7 Trolley 10 7 1 Assembly 10 7 2 Handling 10 8 Mixing tools 11 8 1 Tooling op ons 11 8 2 Adjus ng the height of the mixing tools 11 8 3 Changing the mixing tools 11 8 4 Rim scraper 12 9...

Страница 4: ...Forced action mixer Collomix GmbH Collomatic XM Gaimersheim Germany Page 4 Rev US02 2013 Ref no 39017 1 Components 15 13 11 12 7 6 5 4 2 1 3 10 8 9 14 16...

Страница 5: ...ts the machine from being started up again uninten onally 7 Timer switch Used to select mixing me of 90 sec 180 sec or con nuous mixing mode 8 Jack rings 2x Used to a ach belts for li ing and moving t...

Страница 6: ...Forced action mixer Collomix GmbH Collomatic XM Gaimersheim Germany Page 6 Rev US02 2013 Ref no 39017...

Страница 7: ...l weight 231 lbs 105 kg Sound pressure level 70 dB A Sound power level 85 dB A Manufacturer COLLOMIX GmbH Daimlerstr 9 D 85080 Gaimersheim Telephone 49 84 58 32 98 0 Telefax 49 84 58 32 98 30 e Mail i...

Страница 8: ...plosive atmosphere is decribed by the amount of inflameable particles in the ambient room air which will cause an explosion through heat or sparks FI Breaker special marked a Ground Fault Circuit Inte...

Страница 9: ...working order use it for the intended use only and have proper regard for safety and danger at all mes All faults which may impair safety must be rec ed immediately Wear close ng clothing and safety...

Страница 10: ...ke any material samples Do not operate the machine without the guard cage or without any of the parts of the housing Risk of crushing The consequence of deliberately shu ng o any of the safety func on...

Страница 11: ...me me thin bodied material can be easily poured out using the pouring device on the trolley The numbers given in brackets in these Opera ng Instruc ons refer to the numbers in the layout on page 4 4 1...

Страница 12: ...en using the thumb screw see illustra on It is essen al that the handles be fastened because when li ed the machine can p forward especially on an uneven surface center of gravity Take hold of the car...

Страница 13: ...ou have the tub in balance If you are processing thin bodied materials you can pour them by applying the locking device Pick up the tub as described above Then set the trolley down lengthwise on the o...

Страница 14: ...materials of all viscosi es 8 1 Tooling options Both mixing tools rotate at a speed of 185 rpm Use this tooling op on for mixing all high viscosity viscous and heavy materials such as for example Rea...

Страница 15: ...able from the cable drum to prevent built up of heat cable dam age electric shock fire and production fall out Extreme long cables lead to voltage drop Keep cables away from traffic areas Important no...

Страница 16: ...w If the machine is disconnected from the mains power supply while closed it has to be fully opened and then closed again Then the machine will run again Switching on the power switch 11 3 Stopping Wh...

Страница 17: ...run for 90 seconds before switching o automa cally 180 posi on The mixing tools run for 180 seconds before switching o automa cally Con nuous posi on For switching on o by hand no automa c func on NOT...

Страница 18: ...ec ve Anyone who deliberately removes any safety devices or renders them inopera ve is liable to prosecu on Such an ac on would cause incalculable danger for the user At the same me this would also re...

Страница 19: ...10 V only Replace the opera ng capacitor Machine turns o a er a short me and cannot be restarted Bimetal element triggered machine overload Allow the machine to cool down min 2 minutes if necessary re...

Страница 20: ...cleaner to clean the machine itself This could cause the ball bearings etc to run dry Check the state of the mixing tools for wearing out Replace all damaged or bent mixing tools Make sure that the co...

Страница 21: ...age 21 Rev US02 2013 Ref no 39017 15 1 Circuit diagram 110 Volt 60 Hz 8 blue A1 V U T U2 W2 ST6 7 5 4 3 2 1 6 S4 S3 S2 black brown white brown black brown blue 13 5 3 1 2 4 6 14 K1 A2 A1 2 3 4 5 1 6 0...

Страница 22: ...Collomix GmbH Forced action mixer 85080 Gaimersheim Germany Collomatic XM Ref no 39017 Rev US02 2013 Page 22 Trolley_65_90...

Страница 23: ...Ar kelnr 07001 040 Collomix GmbH P 02 05 13...

Отзывы: