8.4 Rim scraper
9. Use of the correct mixing tub
For guaranteed trouble-free opera琀椀on and consistently sa琀椀sfactory mixing results it is
important that you use the original mixing tub.
This is a round 17 gallon plas琀椀c tub made of impact-resistant PE material.
Tubs made by other manufacturers do not normally have the same dimensions and this will
prevent the rim scraper form working properly. If a higher tub is used it may not be possible
to close the machine.
Please contact your local dealer for the right original tub.
The machine will not start up unless the mixing tub is in place!
10. Power connection
Prior to any electrical connections of the machine - follow these instructions.
Observe any electrical safety precausions, which are mandatory at the place of operation.
At building sites use the approved electrical supply, with FI-breaker and 0,05 Amp. fault
current. Do not connect to common house outlets.
Make sure, to prevent accidential damage to cables und electrical components.
Rubber cables of the type SJNW 3 x 13 AWG and propper connector must be used.
Unroll the full lenght of cable from the cable drum, to prevent built-up of heat, cable dam
-
age, electric shock, fire and production fall out.
Extreme long cables lead to voltage drop.
Keep cables away from traffic areas.
Important note:
110 volt machines are delivered with supply cable without electric plug! Make sure that the
corresponding plug is installed by an approved electrician.
The rim scraper is adjusted at the factory. If you readjust it you must take care to ensure that
the arm of the rim scraper does not scrape against the rim of the tub.
Adjust the rim scraper so that it is as close as possible to the rim and bo琀琀om of the tub.
However, it must not be in contact with these surfaces. Use the hexagon nut to make the
adjustments.
The mixing tools are 昀椀琀琀ed and adjusted at the factory. To remove them, loosen the locking
nut slightly with an open-ended wrench while holding the mixing tool with a second open-
ended wrench
Unscrew the mixing tool.
If you are not going to replace the tool with another one, screw the threaded plug onto
the threaded spindle to prevent it from ge琀�ng soiled. Remember to take account of the
di昀昀erent thread sizes, M 16 and M 18.
When you screw a mixing tool to the spindle, always check the distance between the tool
and the bo琀琀om of the tub. The tool must never come into contact with the bo琀琀om of the
tub! Then re琀椀ghten the locking nut against the mixing tool.
8.3 Changing the mixing tools
Содержание XM 2-650
Страница 2: ...Forced action mixer Collomix GmbH Collomatic XM Gaimersheim Germany Page 2 Rev US02 2013 Ref no 39017...
Страница 6: ...Forced action mixer Collomix GmbH Collomatic XM Gaimersheim Germany Page 6 Rev US02 2013 Ref no 39017...
Страница 23: ...Ar kelnr 07001 040 Collomix GmbH P 02 05 13...