13. Troubleshooting
Symptom
Possible Problem
Solu琀椀on
Mixer does not start
ON/OFF switch is set manually to "0"
Open the mixer, set ON/OFF switch to "1"
and close the mixer again
Cable too long and/or cable cross-sec琀椀on
not large enough
Check cable cross-sec琀椀on; must be 2.5
mm². Reduce cable length.
Plug not connected?
Check if plugs are connected
No power from main power supply?
Check main power supply
No mixing tub in the machine?
Insert mixing tub correctly
Incorrect mixing tub in mixer?
Use the correct model of mixing tub
Defec琀椀ve start-up capacitor
(110 V only
)
Replace the start-up capacitor
Defec琀椀ve opera琀椀ng capacitor
(110 V only
)
Replace the opera琀椀ng capacitor
Machine turns o昀昀 a昀琀er a
short 琀椀me and cannot be
restarted
Bimetal element triggered (machine
overload)?
Allow the machine to cool down (min.
2 minutes); if necessary reduce the
amount of mixing material
Cable too long and/or cable cross-sec琀椀on
not large enough?
Check cable cross-sec琀椀on; must be 2.5
mm². Reduce cable length.
Plug got disconneted?
Reconnect plug to power outlet
Loss of power in the mains power supply? Check the mains power supply
Defec琀椀ve start-up capacitor
(110V only)
Replace the start-up capacitor
Defec琀椀ve opera琀椀ng capacitor
(110V only)
Replace the opera琀椀ng capacitor
Damage to the mixing tub or
the mixing tools
Mixing tools set too low
Set the mixing tools to the correct height
(see Sec琀椀on 8.2)
Deposits of residual material
collec琀椀ong at the bo琀琀om of
the tub
Mixing tools set too high or worn out
Check Mixing tools /
set the mixing tools
to the correct height (see Sec琀椀on 8.2)