11. Using for the first Time
• Take hold of the handle and the latch bar. Pull them towards you. This opens the
lock.
• Pull the swivel arm upwards.
• The machine now stands open in front of you. In the mixing tub you will 昀椀nd two
open-ended wrenches and one other tool. Take these out and check that the tub is
empty.
• To close the machine, actuate the latch bar again as described above.
• Press the swivel arm down.
• Release the latch bar while doing so. It will lock into place on its own.
11.1 Opening and closing the machine
11.2 Switching on
•
The machine must be open.
• The mixing tub must be 昀椀lled and posi琀椀oned in the machine with the help of the trolley.
The tub must sit correctly in the tub mount.
•
Switch the power switch to "1".
•
Unlock the swivel arm and press it down un琀椀l it locks.
For the 3-phase version:
Observe the direc琀椀on of rota琀椀on indicated by the arrow.
If the machine is disconnected from the mains power supply while closed, it has to be fully
opened and then closed again. Then the machine will run again.
Switching on the
power switch
11.3 Stopping
When the set 琀椀me cycle has been completed
the machine switches o昀昀 automa琀椀cally.
The
power switch remains at “1”.
If you close the machine again the set 琀椀me cycle will start
running again from the beginning.
If
“Con琀椀nuous mode”
is set the machine will stop when it is opened, or it has to be
switched
o昀昀 manually.
To do so, switch the power switch from “1” to “0”.
If you open the swivel arm
while mixing is in progress the machine will stop immediately.
The power switch remains at “1”.
The machine will start up again when you close the swivel
arm. If a 琀椀me cycle has been set it will start running again at the beginning.
A昀琀er opening you should then remove the mixing tub with the help of the trolley.
NOTE:
Please follow the manufacturer’s processing instruc琀椀ons.
Never start the machine if there is any hardened material in the mixing tub or if any of the
mixing tools are jammed.
Always make sure the machine is at a total stands琀椀ll before you ever take any material