Sea Tel 9711-56 IMA
Maintenance
17-13
EAR Controlled - ECCN EAR99
17.4.1.
Fine Balance and Monitoring Motor Drive Torque
The GRAPHS
DISPTC
graph chart provides a means for monitoring torque commands required for
each motor for diagnostic purposes and verifying antenna balance. By observing each trace, the
required drive of the antenna via the motor driver PCB may be established.
•
To view the Torque Commands, select the
graph chart.
•
This chart displays the Torque Command errors for each axis via three traces, CL (Cross
Level), LV (Elevation), and AZ (Azimuth), at a fixed 0.195 amps/vertical division.
•
In all axes, tracing centered on the reference line means that that axis is neutral. Tracing
above
the reference line means that that axis is driving CCW. Tracing
below
the reference
line means that that axis is driving CW.
•
A normal trace display will be ± 1 divisions from the red reference line while under calm sea
conditions and with DishScan® Drive turned off. See example below
•
The Cross Level displayed above the reference line indicates that CL is driving CCW (Left).
Example: The antenna pictured in the screen capture below is imbalanced so that it is “Right
Heavy”. The CL trace is plotting above the red reference line (indicating that drive CCW is
required to keep the Cross-Level beam level (to the horizon).
•
The Level display will plot below the reference line when the antenna requires CW drive (Up
in elevation).
Содержание Sea Tel 9711-56 IMA C Band
Страница 12: ...Safety Sea Tel 9711 56 IMA 1 2 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 24: ...Site Survey Sea Tel 9711 56 IMA 3 8 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 122: ...Quick Start Operation Sea Tel 9711 56 IMA 14 6 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 128: ...Installation Troubleshooting Sea Tel 9711 56 IMA 16 4 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 146: ...Stowing the Antenna Sea Tel 9711 56 IMA 18 4 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 160: ...Drawings Sea Tel 9711 56 IMA 20 2 EAR Controlled ECCN EAR99 This Page Intentionally Left Blank...
Страница 174: ......
Страница 175: ......
Страница 176: ......
Страница 201: ...INSTRUCTION NUMBER REV 97 156574 B SHEET 3 OF 4 STEP 3 STEP 4 E INSTALL ROTARY JOINT F INSTALL POLANG MOTOR ASSY...
Страница 213: ......
Страница 214: ......
Страница 225: ......
Страница 226: ......
Страница 233: ......
Страница 234: ......