51
EQ 1000
MOTORIZED WHEEL BALANCER WITH DIGITAL DISPLAY
Automatic acquisition of the wheel dimensions for the STD and ALU1,2,3,4,5,Programme Types
To introduce the wheel size automatically, proceed as follows:
Machines with Width sensor
1. Assemble the wheel on the shaft;
2. Extract both sensors and rest them on the rim as shown in Figure 3.6;
3. Wait to hear the long acquisition beep and then set the sensors back to the rest position. During acquisition, the
distance and diameter values are shown on the display.
Note: the width is not displayed during automatic acquisition but to verify the newly acquired value, simply press
[P2].
It is possible to extract the Width sensor alone and view the width that refers to the last distance acquired (manually
or automatically), but there will be no acquisition in this case. However, if you also extract the distance/diameter
sensor, the display with the width will be removed and the acquisition as described in point 3 will start.
Machines without the Width sensor
1. Assemble the wheel on the shaft;
2. Extract the Distance/Diameter sensor and place it on the rim as shown in Figure F3.6.
3. Wait to hear the long acquisition beep and then set the Distance/Diameter sensor back to the rest position;
4. Introduce rim width manually. The width of the rim is normally printed on the rim itself.
Alternatively, use the appropriate width
measuring gauge.
Automatic acquisition of the wheel dimensions for the ALS1 and ALS2 Programme Types
To automatically enter the dimensions of the wheel in the ALS1 and ALS2 Programme types, proceed as follows:
1. Assemble the wheel on the shaft;
2. Extract the Distance/Diameter sensor and place it on the plane chosen as the internal plane. The point of support
differs depending on whether the ALS1 or ALS2 programme has been enabled. See fi gures F3.7 and F3.8;
3. Wait to hear the long acquisition beep and then set the sensor back to the rest position;
4. Extract the Distance/Diameter sensor and place it on the plane chosen as the external plane. See fi gure
F3.9;
5. Wait to hear the long acquisition beep and then set the sensor back to the rest position;
6. The dimensions of the wheel have been acquired and the values can be displayed and/or modifi ed by pressing
[P1] for the di1/di2 values (internal/external plane distance) and [P3] for the da1/da2values (internal/external
diameter plane).
Figure F3.6. Automatic data acquisition
in the STD, ALU1,2,3,4,5 programmes
Содержание EQ 1000
Страница 29: ...29 EQ 1000 EQUILIBREUSE ROUES MOTORISEE AFFICHAGE DIGITAL ...
Страница 75: ...NOTES ...