1-81
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G145 Connect a Multishelf Node and Subtending Shelves to an MS-ISC-100T Card
Step 6
Return to your originating procedure (NTP).
NTP-G145 Connect a Multishelf Node and Subtending Shelves to
an MS-ISC-100T Card
Step 1
To connect the MS-ISC-100T cards to the node controller shelf and set up protection, complete the
following substeps (see
). For more information on MS-ISC-100T card port assignments,
refer to the “Common Control Cards” chapter in the
Cisco ONS 15454 DWDM Reference Manual
.
a.
Using the 5.9 in. (0.15 m) CAT-5 LAN cable, plug one connector into the NC port of the
MS-ISC-100T card located on the left side of the node controller shelf (Slots 1 to 6) and plug the
other connector into the front panel (RJ-45 connector) of the TCC2/TCC2P card in Slot 7.
b.
Using the 5.9 in. (0.15 m) CAT-5 LAN cable, plug one connector into the NC port of the
MS-ISC-100T card located on the right side of the node controller shelf (Slots 12 to 17) and the
other end into the front panel (RJ-45 connector) of the TCC2/TCC2P card in Slot 11.
c.
Using the 19.69 in. (0.5 m) CAT-5 LAN cable, plug one connector into the PRT port of the
MS-ISC-100T card located on the left side of the node controller shelf (Slots 1 to 6) and plug the
other connector into the NC port of the MS-ISC-100T card located on the right side of the node
controller shelf (Slots 12 to 17).
d.
Plug the nine connectors on one end of the EAP cable into the two DCN ports and the seven
subtending shelf controller (SSC) ports of the MS-ISC-100T card located on the left side of the node
controller shelf (Slots 1 to 6). Plug the other end of the EAP cable into the multishelf port on the left
EAP.
e.
Plug the nine connectors on one end of the EAP cable into the two DCN ports and the seven SSC
ports of the MS-ISC-100T card in the right side of the NC shelf (Slots 12 to 17). Plug the other end
of the EAP cable into the multishelf port on the right EAP.
Purpose
Use this procedure to connect a multishelf node and subtending shelves to
two MS-ISC-100T cards.
Tools/Equipment
5.9 in. (0.15 m) CAT-5 LAN cable (2)
19.69 in. (0.5 m) CAT-5 LAN cable (1)
Cross-over (CAT-5) LAN cables (2 for each subtending shelf)
84 in. (2.13 m) EAP cables (2)
Prerequisite Procedures
NTP-G15 Install the Common Control Cards, page 1-75
DLP-G371 Install the Ethernet Adapter Panel, page 1-70
Required/As Needed
As needed
Onsite/Remote
Onsite
Security Level
None