1-82
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G145 Connect a Multishelf Node and Subtending Shelves to an MS-ISC-100T Card
Figure 1-34
Connecting the EAP to the Node Controller and Subtending Shelf
Step 2
To connect a subtending shelf to the EAP, complete the following (see
):
a.
Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending
shelf TCC2/TCC2P card in Slot 7 and plug the other end into the SSC1 port on the left EAP.
b.
Using a cross-over (CAT-5) LAN cable, plug one connector into the front panel of the subtending
shelf TCC2/TCC2P card in Slot 11 and plug the other end into the SSC1 port on the right EAP.
c.
Repeat Steps
and
for each subtending shelf in the multishelf configuration. Use the same SSC
port number (2 through 8) on the left and right EAP for each subtending shelf.
Stop. You have completed this procedure.