1-77
Cisco ONS 15454 DWDM Procedure Guide, R8.0
78-17704-02
Chapter 1 Install the Shelf and Common Control Cards
NTP- G33 Install the TCC2 or TCC2P Card
Note
It is possible to close the latches/ejectors when the card is not completely plugged into the back
panel of the shelf assembly. Ensure that you cannot insert the card any farther.
If you insert a card into a slot provisioned for a different card, all LEDs turn off.
Step 4
As needed, go to Step
to verify the LED activity on the TCC2 card. For the TCC2P card, go to Step
a.
For the TCC2 card:
•
All LEDs turn on briefly. The red FAIL LED and the yellow ACT/STBY LED turn on for about
15 seconds.
•
The red FAIL LED and the green ACT/STBY LED turn on for about 40 seconds.
•
The red FAIL LED blinks for about 15 seconds.
•
The red FAIL LED turns on for about 15 seconds. All LEDs turn on for about 3 seconds before
turning off for about 3 seconds.
•
Both green PWR LEDs turn on for 10 seconds. The PWR LEDs then turn red for 2 to 3 minutes
before going to steady green.
•
While the PWR LEDs are red for two to three minutes, the ACT/STBY turn on.
•
The boot-up process is complete when the PWR LEDs turn green and the ACT/STBY remains
on. (The ACT/STBY LED will be green if this is the first TCC2 card installed, and amber if this
is the second TCC2 card installed.)
b.
For the TCC2P card:
•
All LEDs turn on briefly. The red FAIL LED, the yellow ACT/STBY LED, the green SYNC
LED, and the green ACO LED turn on for about 15 seconds.
•
The red FAIL LED and the green ACT/STBY LED turn on for about 30 seconds.
•
The red FAIL LED blinks for about 3 seconds.
•
The red FAIL LED turns on for about 15 seconds.
•
The red FAIL LED blinks for about 10 seconds and then becomes solid.
•
All LEDs (including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs) blink once and turn
off for about 5 seconds.
•
Both green PWR LEDs turn on for 10 seconds. The PWR LEDs then turn red for 2 to 3 minutes
before going to steady green. During this time, the ACT/STBY, MJ, and MN LEDs might turn
on, followed by the SNYC LED briefly.
•
The boot-up process is complete when the PWR LEDs turn green and the yellow ACT/STBY
remains on. (The ACT/STBY LED will be green if this is the first TCC2 card installed, and
yellow if this is the second TCC2 card installed.)
Note
It might take up to four minutes for the A and B power alarms to clear.
Note
If you are logged into CTC, the SFTWDOWN alarm might appear as many as two times while
the TCC2 card initializes. The alarm should clear after the card completely boots.