9-105
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 9
Troubleshooting Commands
dspenvalms
Power Supply A1 none None none Normal
Power Supply A2 none None none Normal
Power Supply A3 none None none Normal
DC Voltage A 42 to 54 VoltsDC 49 Normal
Power Supply B1 none None none Missing
Power Supply B2 none None none Missing
Power Supply B3 none None none Missing
DC Voltage B 42 to 54 VoltsDC 0 Normal
Top Fan Tray 1 >= 2000 RPM 3504 Normal
Top Fan Tray 2 >= 2000 RPM 3498 Normal
Top Fan Tray 3 >= 2000 RPM 3576 Normal
Top Fan Tray 4 >= 2000 RPM 3498 Normal
Top Fan Tray 5 >= 2000 RPM 3480 Normal
Top Fan Tray 6 >= 2000 RPM 3570 Normal
Top Fan Tray 7 >= 2000 RPM 3468 Normal
Top Fan Tray 8 >= 2000 RPM 3366 Normal
Top Fan Tray 9 >= 2000 RPM 3444 Normal
Bottom Fan Tray 1 >= 2000 RPM 0 Missing
Bottom Fan Tray 2 >= 2000 RPM 0 Missing
Bottom Fan Tray 3 >= 2000 RPM 0 Missing
Bottom Fan Tray 4 >= 2000 RPM 0 Missing
Bottom Fan Tray 5 >= 2000 RPM 0 Missing
Bottom Fan Tray 6 >= 2000 RPM 0 Missing
Bottom Fan Tray 7 >= 2000 RPM 0 Missing
Bottom Fan Tray 8 >= 2000 RPM 0 Missing
Bottom Fan Tray 9 >= 2000 RPM 0 Missing
+5V Input 4.850^ to 5.150^ VoltsDC 5.017 Informational
+3.3V Input 3.200^ to 3.400^ VoltsDC 3.259 Informational
+2.5V Input 2.425^ to 2.575^ VoltsDC 2.440 Informational
Calibration VDC 0x7e^ to 0x82^ Other 0x80 Informational