2-93
Cisco MGX 8850 Routing Switch Command Reference
Release 2.0, Part Number 78-10467-04 Rev C0, October 2001
Chapter 2
Shelf Management Commands
setrev
Example
Specify version 2.0(2) for the card in slot 9. In addition to setrev, this example shows other commands
you could use before and after setrev. The sequence begins with a display of all the cards. While the
firmware is going into the RAM on the card, periodically execute dspcds on the PXM45 to see the
changing status of the target card. After setrev finishes, execute dspcd on the targeted service module
to see the version and other details of the card or dspversion to see just the version.
Step 1
On the PXM45, use dspcds. The display shows slot 9 has a card with no firmware.
pinnacle.7.PXM.a > dspcds
pxm45tl System Rev: 00.00 Jan. 05, 2000 15:18:40 GMT
Boot F/W Rev: 0.0(0) H/W Rev: 00.00 GMT Offset 0
Backplane Serial No: _UNKNOWN___ Backplane HW Rev: 00.00
Statistics Master IP Address: 0.0.0.0 Shelf Alarm: NONE
Card Front/Back Card Alarm Redundant Redundancy
Slot Card State Type Status Slot Type
--- ---------- -------- -------- ------- -----
01 Empty --- --- --- ---
02 Empty --- --- --- ---
03 Empty --- --- --- ---
04 Empty --- --- --- ---
05 Empty --- --- --- ---
06 Empty --- --- --- ---
07 Active/Empty UNKNOWN_FC NONE 08 PRIMARY SLOT
08 Empty Resvd/Emp UNKNOWN_FC MAJOR 07 SECONDARY SLOT
09 Failed/Empty UNKNOWN_FC NONE NA NO REDUNDANCY
10 Empty --- --- --- ---
11 Empty --- --- --- ---
12 Empty --- --- --- ---
13 Empty --- --- --- ---
14 Empty --- --- --- ---
Step 2
Change directories to the “FW” (firmware) directory.
pinnacle.7.PXM.a > cd /FW
Step 3
List the contents of the directory:
pinnacle.7.PXM.a > ls
The display shows the names of the firmware files. Extract the AXSM version number—2.0(2):
pxm45_002.000.001-D.fw
pxm45_002.000.014-A1_bt.fw
axsm_002.000.002.fw
Step 4
Type setrev and specify version 2.0(2) as the primary firmware version for slot 9.
pinnacle.7.PXM.a >
setrev
9 2.0(2)