Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 11 Viewing and Responding to Alarms
Displaying Alarm Reports in the CLI
Bottom Fan Tray 1 >= 2000 RPM 0 Missing
Bottom Fan Tray 2 >= 2000 RPM 0 Missing
Bottom Fan Tray 3 >= 2000 RPM 0 Missing
Bottom Fan Tray 4 >= 2000 RPM 0 Missing
Bottom Fan Tray 5 >= 2000 RPM 0 Missing
Bottom Fan Tray 6 >= 2000 RPM 0 Missing
Bottom Fan Tray 7 >= 2000 RPM 0 Missing
Bottom Fan Tray 8 >= 2000 RPM 0 Missing
Bottom Fan Tray 9 >= 2000 RPM 0 Missing
+5V Input 4.850^ to 5.150^ VoltsDC 5.036 Informational
+3.3V Input 3.200^ to 3.400^ VoltsDC 3.298 Informational
Type <CR> to continue, Q<CR> to stop:
MGX8830 Node Alarm: MINOR
ENVIRONMENTAL ALARM STATE INFO ^Notification Disabled
Alarm Type Unit Threshold DataType Value State
---------------- ---- -------------- -------- ---------- -------------
Fan Tray 6 >= 2000 RPM 2766 Normal
Fan Tray 7 >= 2000 RPM 2676 Normal
Fan Tray 8 >= 2000 RPM 2610 Normal
+5V Input 4.850^ to 5.150^ VoltsDC 4.997 Informational
+3.3V Input 3.200^ to 3.400^ VoltsDC 3.259 Informational
Calibration VDC 0x7e^ to 0x82^ Other 0x80 Informationall
Displaying Card Alarms
A card alarm report can display the alarm status of all the cards within the node or the alarm status of a
single card. To display card alarms, enter the following command at the PXM45 or PXM1E switch
prompt:
mgx8830a.2.PXM.a>
dspcdalms
[
slot
]
Replace [slot] with the number of the card for which you want to display alarms. If you omit the slot
number, the switch displays the alarms for all cards in the node as shown in the following example:
M8830_CH.1.PXM.a >
dspcdalms
Card Alarm Summary
Slot Critical Major Minor || Slot Critical Major Minor
---- -------- ------- ------- || ---- -------- ------- -------
1 1 0 0 || 8 0 0 0
2 0 0 0 || 9 0 0 0
3 0 0 0 || 10 0 0 0
4 0 0 0 || 11 0 0 0
5 0 0 0 || 12 2 2 0
6 0 0 0 || 13 0 0 0
7 0 0 0 || 14 0 0 0
Use dspcdalms <slot> to see more detail.