8-47
Cisco MGX 8850 (PXM1E/PXM45), Cisco MGX 8950, Cisco MGX 8830, and Cisco MGX 8880 Configuration Guide
Release 5.0.10, OL-3845-01 Rev. B0, August 16, 2004
Chapter 8 Managing PNNI Nodes and PNNI Routing
Managing Connection Grooming
Displaying Nodal Grooming Configuration Parameters
To display nodal grooming configuration parameters, enter the dspndrteopt command as shown in the
following example:
PXM1E_SJ.7.PXM.a >
dspndrteopt
Nodal Route Optimization Parameters:
------------------------------------
Orderly Grooming Feature: Enabled
Orderly Grooming Batch Size: 20
Orderly Grooming Timeout: 300
Trunk Util Threshold Percent: 85
Soft Reroute: Enabled
Displaying Grooming Configuration Statistics
To display the current grooming statistics, enter the dsprteoptstat command as shown in the following
example:
PXM1E_SJ.7.PXM.a >
dsprteoptstat
Route Optimization Status:
----------------------------------
Req=Requests, Eval=Evals, Att=Attempts
Orderly Grooming: Rrt=Reroutes, Tme=TimedOuts, Can=Cancels
Soft Reroute: Att=Attempts, FIc=Failed Incumbent, Lcb=Late CallBk
Rrt=Reroutes, FRr=Failed Rerouting, Lrl=Late Release
Orderly Grooming Soft Reroute
---------------- ----------------
Port Status Req Eval Att Rrt Tme Can Att FIc Lcb
Rrt FRr Lrl
9.2 done 0 0 0 0 0 0 0 0 0
0 0 0
11.1 done 0 0 0 0 0 0 0 0 0
0 0 0
11.5 done 0 0 0 0 0 0 0 0 0
0 0 0
The grooming statistics column head abbreviations are described above the command display.
Configuring the AIS Delay
An alarm indication signal (AIS) is sent to CPE at each end of a connection when the switch detects a
connection alarm. The derouting of a connection triggers the AIS signal, and depending on the CPE
configuration, the derouting may trigger a switchover of the CPE to backup facilities. The AIS delay
timer feature is designed to delay a locally generated AIS event long enough that a new connection can
be established during grooming. If the new connection is established before the end of the AIS delay, no
AIS is generated.
Note
The AIS delay does not affect AIS signals generated on other switches and forwarded to this switch.