B-4
Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-04
Appendix B Connector and Cable Specifications
Connector Specifications
AC Power Supply Connector
For detailed information about the hardware described in this section, the
“Router Hardware
Description”
chapter.
Non-Cisco Module Power Connector
This section provides the following information for the power connector for installing external,
non-Cisco modules on the router:
•
Power wiring specifications, in the
“Non-Cisco Module Power Connector Specifications”
in
Table B-7 on page B-4
. .
Note
The cable that you provide to connect the module to the 12V power connector must be wired
so that Pin 3 (cable presence) and Pin 4 (ground) are connected to each other. If they are not
connected, the module will not detect power from the router.
•
Power connector parts, and compatible parts, in the
“Non-Cisco Module Power Connector
Specifications”
in
Table B-8 on page B-5
.
For more information about non-Cisco modules, see the
“Installing External Non-Cisco Modules”
chapter.
Table B-6
AC Power Supply Connector Specification
Pin
Signal Name
Signal Description
1
L
AC line
2
N
AC neutral
3
Chassis
Chassis ground
Table B-7
Non-Cisco Module Power Connector Specifications
Pin
Signal Name
Signal Description
1
12V
12V power from router
2
GND
System ground
3
CBL_PRSENT_L
Cable presence detect
4
GND
System ground