12-29
Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-04
Chapter 12 Installing Battery Backup Units
Related Commands
To display battery data information, use the
show platform battery
command in user EXEC mode. The
command syntax is:
show platform battery
[
brief
|
cable
|
details
|
short
|
sprom
|
unit
]
Syntax Description:
The following are examples of the command, with sample output:
CGR1240#
show platform battery
Battery is not present
Battery pack state: Not available
The command output indicates a battery is not present.
CGR1240#
show platform battery brief
Battery level 92% (12:27), Idle
The command output indicates that the battery is charged to a 92% level, has q2 hours and 27 minutes
battery life available, and is in an idle state.
CGR1240#
show platform battery cable
Status register 0x16
brief
(Optional) Displays summary information about the battery charge level in
percentage and hours:minutes formats, as well as the battery charge state:
•
Idle, if > 85%
•
Charging, if voltage > 10.5 V and charge value < 85%.
•
Discharging, if battery is main source of power.
•
Empty, if battery is drained out of charge.
cable
(Optional) Displays details about the battery cable status:
•
present = 0, in the command output means that a battery cable is not
present.
•
present = 1, in the command output means that a battery cable is
present.
details
(Optional) Displays troubleshooting information about the battery by
presenting a range of summary information about the battery
characteristics.
short
(Optional) Displays backup battery information in short format (formatted
for a management device).
sprom
(Optional) Displays troubleshooting information based on the eeprom
details of the battery unit.
unit
(Optional) Displays a range of battery charge, capacity, and parameter
information including:
•
battery charge state and charge value/level in percent.
•
capacity (remaining and full charge).
•
voltage and current levels.
•
firmware version details.