Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-04
Chapter 12 Installing Battery Backup Units
Related Commands
Once the BBU is connected, the only way to disable is to use the
backup-battery disable
command. To
enable the BBU again, issue the
backup-battery enable
command.
backup-battery reset
Note
The
backup-battery reset
command only works on routers using the Cisco CG-OS operating system.
To reset the BBU power (power off the BBU, then power it back on), use the
backup-battery reset
command in user EXEC mode:
CGR1240#
backup-battery reset
This command is functional only when AC power is supplying power to the router. If you enter this
command when the router is powered by the BBU, an error message is displayed.
This command resets all BBUs installed in the router.
backup-battery hard-reset
Note
The
backup-battery hard-reset
command only works on routers using the Cisco CG-OS operating
system.
To reset the BBU power (power off the BBU, then power it back on) while you cannot communicate with
the BBU through the UART interface, use the
backup-battery hard-reset
command in user EXEC
mode:
CGR1240#
backup-battery hard-reset
This command resets all BBUs installed in the router.
backup-battery inhibit discharge
Note
The
backup-battery inhibit discharge
command only works on routers using the Cisco CG-OS
operating system.
Note
When the BBU discharge is disabled by the
backup-battery inhibit discharge
command, the BBU does
not charge, even if it is connected to AC power. The BBU discharge must be enabled by the
backup-battery un-inhibit discharge
command, and the BBU connected to AC power, for the BBU to
charge.
To disable the BBU automatic discharge feature, use the
backup-battery inhibit discharge
command
in user EXEC mode. Use this command to disable the BBU automatic discharge when you disconnect
the router from AC power, and want to prevent the BBU from automatically discharging; for example
when you are shipping the router, or transporting it between locations. When the BBU discharge is
disabled, the BBU LED displays the amber slow blinking state. Use the
backup-battery un-inhibit
discharge
command to enable the BBU automatic discharge after disabling it.
The
backup-battery inhibit discharge
command has two effects: