![chromasens 3DPIXA Скачать руководство пользователя страница 87](http://html1.mh-extra.com/html/chromasens/3dpixa/3dpixa_manual_2605699087.webp)
7 Camera parameters
3DPIXA
CD40131 Version 1
87 / 99
7.6.2
Synchronization mode
Function
Select “Line trigger” or “Encoder mode”.
Dependency
Only active with active “Enable Encoder”.
Notes
For the use of this mode, the external ports have to be connected to the
internal function by using the IO-Configurator of CST.
Line trigger
With the line trigger the camera will send one line per pulse.
Fig. 54: Line trigger and camera pulses
1
Line trigger
2
Integration time
Encoder mode
The camera measures the distance of the signals and will send lines with the requested
resolution. An internal line trigger will be generated. The user has to set the desired transport
and encoder resolution in the CST.
Fig. 55: Encoder, line trigger and camera pulses
1
Encoder pulses per line trigger (e. g. 2.25)
2
Encoder pulses
3
Line trigger
4
Integration time
Minimum pulse duration:
CP000520 models: 45 ns
CP000470 models: 60 ns
Shorter pulses will be ignored.
Minimum speed with encoder mode:
𝑉
𝑚𝑖𝑛
=
𝑚𝑚/𝐸𝑛𝑐𝑜𝑑𝑒𝑟 𝑝𝑢𝑙𝑠𝑒
0.59 𝑠