6 Setting up the 3D scanner system
66 / 99
CD40131 Version 1
3DPIXA
2. Set the scan direction for the 3D calibration via the configuration file:
Fig. 36: Setting the scan direction for the 3D calibration
For setting the scan direction via the 3D-Viewer, select the menu items
Calculation >
Options > Miscellaneous > Scan Direction
.
The
InvertTransportDirection
parameter in the configuration file has two states:
–
InvertTransportDirection
= 0: Forward scan direction (default)
–
InvertTransportDirection
= 1: Backward scan direction
For setting the scan direction via the CS-API, refer to the CS-API manual.
6.10 Adjusting the integration and line period times
1. Open the CST.
2. Select the COM port where the camera is connected (COM port of the frame grabber).
3. In the
Camera Settings
select
Integration time
in the
Camera Parameter
folder.
Fig. 37: Camera Parameter
– Integration time
4. Enter the integration time and the line period time in the corresponding input fields.
The input field for the line period time is only active if a checkmark is set in the
Use line
period
field.
5. Save the settings to the non-volatile memory of the camera by selecting the
corresponding icon in the toolbar or by pressing the F9 key on the PC keyboard.
If the 3DPIXA dual camera is used, the settings have to be done only in the master camera.