95
Part 8:
COMPONENT REPAIR AND REPLACEMENT
Replacing the Wash Pump Seal:
1. Remove the 8 mm drain plug in the
pump volute and drain the pump.
2. Remove (9) pump housing screws.
3. Remove the impeller retaining hardware.
MOTOR SHAFT HAS LEFT-HAND
THREADS. TURN IMPELLER CW TO
REMOVE.
4. Remove the defective seal.
Save the shim washer
5. Install the replacement seal.
Stationary portion goes in the pump housing.
Rotating portion mounts on the shaft.
6. Reassemble in reverse order.
Motor
Capacitor
Red
Red
White
White
31
WC
32
L1
N
20
2
Single Phase Motor Wiring Diagram
Capacitor
Assembly
Impeller
(Left hand Thread)
Seal Assembly
Shim Washer
(Do not Discard)
Drain
Plug
Impeller Nut
and Washers
Ceramic Face
Carbon Face
Stationary
Portion
of Seal
Assembly
Rubber Boot
Rotating
Portion
of Seal
Assembly
SEAL ASSEMBLY DETAIL
8.2.10 Wash Pump/Motor (All Models)
Содержание UH-200