9
Part 2:
INSTALLATION
2.4.1 (Water Connections) Models UH-200B, UH-200
Refer to the Table below for minimum water supply requirements.
1. If flowing pressure exceeds 22 PSI/151kPa, a pressure reducing valve, PRV, must be
installed in the incoming water supply, and adjusted to the min/max listed above.
The PRV is supplied by others or may be purchased (unmounted) from Champion.
2. Champion supplies a 3/4" line strainer (unmounted) and shipped inside the dishwasher.
The line strainer must be installed in the water supply line upstream from the PRV.
3. A 3/4" manual shutoff valve (supplied by others) should be installed in the water supply
line upstream from the PRV and line strainer. The valve must be the same size as or larger
than the water supply line. The shutoff valve allows for servicing of the machine.
4. The dishwasher is supplied with a 1/2" I.D., 6 ft. [1829mm], reinforced flexible hose.
The hose is fitted with a 3/4" female garden hose fitting.
CAUTION:
The reinforced fill hose supplied with the dishwasher is designed for high pressure and
high temperature application and should never be replaced with common garden hose.
5. Connect a 3/4" I.D. minimum copper water supply line fitted with a 3/4" male garden hose
fitting (supplied by others). Make sure the water supply line is flushed out before making
connection to the machine.
!
Minimum
Minimum-Maximum
Incoming Water Supply
Water Supply
Model
Temperature
Flowing Pressure*
UH-200B with
40
°
F/22
°
C Booster
140
°
F/60
°
C
20-22 PSI (138-151 kPa)
UH-200B-70 with
70
°
F/39
°
C Booster
110
°
F/43
°
C
20-22 PSI (138-151 kPa)
UH-200 without
Booster
180
°
F/82
°
C
20-22 PSI (138-151 kPa)
*Flowing pressure is observed when the fill water solenoid valve is open while the
machine is in a final rinse operation. Refer to Part 3, Operation, Section 3.21. for a
description of the front panel display final rinse pressure readings.
Figure 2.4.1
Water Connections
Model UH-200B, UH-200
(UH-200B shown)
3/4" Water shutoff Valve
3/4" line strainer
3/4" PRV, pressure reducing valve
6 ft. [1829mm] flexible fill hose
3/4" I.D. copper water supply line
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...