81
Part 8:
COMPONENT REPAIR AND REPLACEMENT
8.1.2 Electrical Component Locator Diagram
Component Descriptions
Wash pump:
Mounted right side of base.
Drain pump/
Mounted rear of base.
Drain valve:
Drain pump works simultaneously with drain valve to pump water
out of the dishwasher
Wash pump
Mounted on bracket right front of base.
contactor:
120VAC from timer control board energizes contactor coil.
Wash tank
Mounted on bracket right front of base.
heat contactor:
120VAC from temperature/display board energizes contactor coil.
Main power
Mounted on bracket right front of base.
terminal block:
Main incoming power connection point.
10 point
Mounted on bracket right front of base.
terminal block:
Connection point between control cabinet to lower components.
Booster tank
Mounted on bracket upper front of base.
heat contactor:
120VAC from temperature/display board energizes contactor coil.
Installation/
Mounted on bracket upper left side of base.
service switch:
Fills booster on initial start-up. (UH-200B only)
Circuit
Mounted on bracket upper left side of base.
breaker:
8 amp manual reset breaker protects 120VAC control circuit.
Booster
Mounted left side of base.
tank:
Heats final rinse water. (UH-200B only)
High limit
One mounted on top of booster. One mounted on side of wash tank.
thermostat:
Manual reset. Trips if temperature exceeds 210
°
F/99
°
C.
Thermistor:
Senses temperature and provides an input to temperature/display bd.
•
Wash tank thermistor
provides a thermometer input to the tem-
perature display and provides thermostatic input for wash tank
heat control.
•
Booster tank thermistor
provides thermostatic input for booster
tank heat control on the temperature/display bd.
•
Final rinse thermistor
provides a thermometer input to the tem-
perature display. Thermistor is located in the final rinse manifold
for UH-200B, UH-200 and the fill chute for all other models.
Water level
Mounted left side of tank assembly.
probe:
Senses water level for timer control bd. input (UH-200B, UH-200 only).
Pressure
Mounted left rear top corner of tank assembly in final rinse manifold.
transducer:
Senses water pressure during final rinse and provides display input
to temperature/display bd. (UH-200B, UH-200 only).
Wash tank
Mounted in bottom of wash tank sump.
heater:
Maintains wash tank water temperature at a minimum of 150
°
F/60
°
C.
Door safety
Mounted left front corner of slide-out control cabinet.
switch:
Prevents machine operation if door open or control cabinet pulled out.
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...