7.3 Replacement Circuit Board Set-up
Jumpers are provided on the Timing Control and the Temperature/Pressure Display boards to set
the program for each machine model (See Fig.7.2.1, page 53, for board locations).
Jumpers are set at the factory for new machines and should not require adjustment.
Whenever a board is replaced in the field,
the service technician must set the jumpers on the replacement circuit board to
match the dishwasher model being repaired.
7.3.1 Timer Control Board Program Jumper Settings
The Timer Control Board has three program jumper settings.
JB1— Enables the basic cycle time for all models and water level control for UH-200 series.
Marked “FWR: fresh water rinse,” for UH-200B and UH-200.
JB2— Enables the booster function if the machine is equipped with a built-in booster.
JB3— Enables prime button inputs. Closed for UH-200B and UH-200.
JB3
LIM
DOOR
SW.
DOOR
SW.
LOW
T2
AC
Neutral
T1
Fused
Hot
POWER
DETERGENT
RINSE AID
SANI
DRAIN
WASH
FILL /
RINSE
MID
JB2
JB1
Transformer
Figure 7.3.1
Timer Control Board Jumpers and LED Status Lights
Part 7:
SOLID STATE CIRCUIT BOARDS
= Jumper Open
= UH-200B, UH-200
= UH-200
= Jumper Closed
= FWR
= F & D
= No Booster
= Booster
= Three Prime Switches
= One Prime Switch
= UH-200B
= UH-200B, UH-200B,
JB1
JB2
JB3
Jumper No.
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...