82
8.1 Introduction (Cont.)
8.1.3 Troubleshooting the 10-point Terminal Board
The 10-point terminal board is mounted on a bracket located in the right front corner of the
machine base. The terminal board provides easy access for making voltage checks to most
of the electrical components mounted on the base of the machine.
Voltages are measured between a numbered wire and common (#2).
All voltages are control voltage and should read approximately 120VAC.
120VAC should be present at the terminal if the associated LED on the
board is illuminated.
For example:
If the Drain LED is illuminated on the Timer Control Board, then 120VAC
should be present between Wire #54 and Wire #2.
Part 8:
COMPONENT REPAIR AND REPLACEMENT
Figure 8.1.2
10-Point Terminal Board
26
25
24
2
2
26
25
24
2
2
2
2
4
6
6
54
54
4
To booster contactor coil (HC2)
(UH-200B)
To wash tank heat contactor coil
To drain pump/drain valve
(All models)
To detergent pump (if equipped)
From Temperature/Display Bd.
From Temperature/Display Bd.
From Timer Control Bd.
From Timer Control Bd.
From Timer Control Bd.
From Timer Control Bd.
Not connected
Not connected
To rinse aid pump (if equipped)
To sanitizer pump (if equipped)
Common
Common
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...