2.10 Installing Optional Chemical Pumps (Cont.)
2.10.1 Models UH-200B, UH-200
To install the rinse aid pump:
1. Remove the lower front access panel.
2. Mount the pump on the machine base with two screws.
3. Route the rinse aid tubing out the rear of the machine through the access hole located
above and between the fill and drain hoses.
4. Pump rotation is clockwise. The supply tube connects on the left side of the pump;
the discharge tubing connects on the right side of the pump.
5. Remove the 1/8" plug located in the final rinse manifold.
6. Install the rinse aid check valve. Apply teflon tape to the valve threads to ensure a seal.
7. Route the rinse aid tubing to the rinse manifold and connect to the check valve.
8. Connect the pump motor wires to the harness wires supplied in the kit with wire nuts.
9. Refer to Fig. 2.10.2 on page 22.
Connect the wiring harness to the 10 pin terminal block located on the lower right side of
the machine. Connect the #2 harness wire to the Common (#2) terminal on the block.
Connect the #25 wire to the rinse aid #25 terminal on the block.
10. Refer to Section 2.9.2, page 19, for pump priming and adjustment procedures.
11. Check all connections for leaks.
12. Installation is complete.
Part 2:
INSTALLATION
4-16
4-4
4-5
4-6
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...