8
2.3 Permanent Placement
Special Tools —
•
Bubble level (3 ft.)
Perform the following steps to place the dishwasher in its permanent location.
Refer to the machine diagrams in Section 1.4, Dimensions and Capacities, page 4-5.
1. Before moving the dishwasher into position, inspect the location site to ensure the electrical,
plumbing, and ventilation services (if required) are provided in the correct locations.
Compare the site connections with the dishwasher to ensure they will match when the
machine is set in its permanent location.
NOTE:
Some local codes may require that the dishwasher be sealed to the floor with
silicon or comparable sealing method.
2. Lift the dishwasher and adjust the leveling feet out.
3. Position dishwasher in its permanent location.
• Minimum clearance between the rear of the machine and back wall is 3" [76mm].
• Minimum height of the machine with adjustable feet turned in fully is 33-3/4" [858mm].
4. Place a 3 ft. level on top of the dishwasher or inside the dishwasher on the track assembly
to level the dishwasher front to back. Adjust level by turning the adjustable feet. Level side
to side with the level placed on the top of the dishwasher.
5. Pull the dishwasher out far enough to gain access to the rear and prepare utility
connections. A removable rear access door is located at the back of the machine.
6. Install the rubber pads on the leveling feet prior to returning machine to its permanent
position.
2.4 Water Connections
The following warning and attention statements apply to all dishwasher models.
WARNING:
The installation of this unit must conform to local codes or, in the absence of
local codes, to all National Codes governing plumbing, sanitation, safety and
good trade practices.
!! ATTENTION INSTALLER !!
The dishwashers described in Section 2.4.1 are fitted with 6 ft. [1829mm],
1/2" I.D. flexible fill hoses located at the rear of the machine.
Make sure supply hose does not kink, resulting in a water flow restriction.
NOTE:
Your plumbing installation must allow the machine to be pulled out for repair.
Part 2:
INSTALLATION
Содержание UH-200
Страница 109: ...108 Part 9 REPLACEMENT PARTS Figure 9 4 Door and Door Safety Switch Assembly All Models 1 2 3 4 4 5 6 7 8 9 7 6 10 11 ...
Страница 117: ...116 Part 9 REPLACEMENT PARTS Figure 9 8 Spray Arm Assembly UH 200B UH 200 Upper Spray Arm Assembly 1 2 2 6 7 8 3 4 5 5 ...
Страница 123: ...122 Part 9 REPLACEMENT PARTS Figure 9 11 Wash Pump Motor Assembly All Models 12 13 1 2 3 5 4 6 7 8 9 10 14 11 ...
Страница 127: ...126 Part 9 REPLACEMENT PARTS Figure 9 13 Solid State Controls All Models ...
Страница 135: ...134 Part 9 REPLACEMENT PARTS Figure 9 17 Dishracks Line Strainer PRV All Models 2 3 4 1 ...