Fill/Rinse Water Solenoid Valve (Cont.)
UH-100B, UH-100, UL-100
To remove the valve assembly (Cont.):
6. Pull valve assembly forward and
out of the dishwasher.
7. Remove the coil wires.
8. Remove three retaining screws
in the bonnet and lift the coil
and bonnet off the body.
9. Inspect valve body. If pitted, replace
entire valve assembly. Otherwise,
install repair kit.
10. Remove the retaining nut and extract
the line strainer screen.
11. Flush clean with water. If damaged,
replace screen.
Flow Washer—
Over time the flow washer may swell and
reduce the water passing through the valve.
If you encounter a low fill condition in the
dishwasher, and incoming supply pressure
appears normal, then replace the flow
washer located in the inlet side of the
valve.
12. Reassemble valve in reverse order.
13. Restore water and power and check for
leaks.
8.2.4 Water Level Probe
UH-200B, UH-200
The water level probe mounts to the left
rear corner of the dishwasher. It is nearly
indestructible but may require periodic
inspection and cleaning to ensure the
metal probes are free of lime build-up.
To clean the probe:
1. Push the POWER pushbutton off.
Turn off main incoming power to the
dishwasher.
2. Gently clean the probes with a
non-ferrous scrub pad such as a
scotch-brite pad.
3. Restore power to the machine and
check for proper operation.
Part 8:
COMPONENT REPAIR AND REPLACEMENT
REAR
LEFT
SIDE
Water Level Probe
LOW
MIDDLE
LIMIT
UH-200B, UH-200 Only
Inside Tank
View
120VAC
coil
Repair
kit
Bonnet
Flow
Washer
Line strainer
screen
Valve disassembled
UH-100B, UH-100, UL-100
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor