8.2.3 Fill/Rinse Water Solenoid Valve (Cont.)
UH-200B, UH-200
To remove the valve assembly (Cont.):
7. Remove the coil assembly.
8. Remove the valve bonnet using
strap wrench or pipe wrench.
9. Inspect valve body. If pitted, replace
entire valve assembly. Otherwise,
install repair kit.
10. Reassemble in reverse order.
11. Restore water and power and check for
leaks.
Remove coil
Remove bonnet
Repair
kit
120VAC coil
Valve disassembled
UH-200B, UH-200
UH-100B, UH-100, UL-100
The 3/8" water solenoid valve is both a fill valve when the machine is turned on and a final rinse
valve during the final rinse. The valve coil is 120VAC. A repair kit is available to rebuild the
internal parts of the assembly. In addition, the valve contains a flow restrictor in the outlet of the
valve and a built-in strainer.
To remove the valve assembly:
1. Turn the main water supply to the
machine off.
2. Push the POWER pushbutton off,
if machine is ON, to enter auto-shutdown.
Otherwise, turn machine on then off.
This will bleed pressure off water line.
3. Remove the lower front panel from the
dishwasher. The valve assembly is
located on the left front side.
4. Disconnect valve discharge hose.
5. Remove (2) valve bracket retaining
bolts.
(Continued next page)
Fill/Rinse Valve Assembly
(UH-100B shown)
Part 8:
COMPONENT REPAIR AND REPLACEMENT
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor