Part 2:
INSTALLATION
2.9.2 Models UH-200B, UH-200 (Chemical Adjust and Prime)
The following chemical adjustment information applies to UH-200B and UH-200 only.
Refer to Section 2.9.1, page 18, for a description of the dispenser adjust potentiometers.
1.
The data below will assist in adjusting the time settings for the dispenser pumps:
• The wash tank holds 3.6 US gal. [13.6 liters] of water.
• Initial fill receives three doses of detergent from the detergent pump.
• Detergent is injected in the wash tank through a fitting at the rear of the wash tank.
• Detergent is injected during the first 1 to 16 seconds of the wash cycle.
• The final rinse utilizes 1.1 US gal [4.2 liters] of water per rack.
• Rinse aid is injected into the final rinse manifold. The manifold is located
in the top left rear corner of the dishwasher.
• Rinse aid is injected during the last 11 seconds of the final rinse cycle.
Dispenser pump output rates:
• Detergent-
69 ml/min.
• Rinse aid-
35 ml/min.
Detergent time adjustment-
Turn the POT CW to increase run time from the beginning
of the wash cycle.
Rinse aid time adjustment-
The final rinse cycle is 11 seconds. Turning the POT CW
moves the pump start point backward from the end of the rinse cycle.
2.
The following describes the operation of the chemical prime button.
Refer to Fig. 2.9.4 below.
• The POWER button must be pushed ON to operate the prime button.
• The PRIME button is enabled whenever the temperature display is active.
• The PRIME button operates both dispensing pumps at the same time.
To prime the detergent and rinse aid pumps:
3. Insert pick-up tubes in the chemical bottles.
4. Push POWER button ON.
Machine fills. Temperature is displayed.
5. Open dishwasher door and observe detergent
injection point on rear wall of machine.
6. Push and hold PRIME button until detergent is
observed entering the machine.
7. Push and hold the PRIME button and observe
chemical flowing at the rinse aid injection point
located in the final rinse manifold.
8. Priming is complete.
Figure 2.9.5
Rinse aid injection point
Models UH-200B, UH-200
Rinse aid
injection point
Final rinse
manifold
Champion
POWER
START
EXTENDED
WASH
WASH
RINSE
PRIME
TEMPERATURE
PRESSURE
160 F
Figure 2.9.4
UH-200B, UH-200 Touchpad/Display
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor