Part 8:
COMPONENT REPAIR AND REPLACEMENT
8.2.2 Water Line Strainer
A 3/4" line strainer was shipped unmounted with the UH-200B, UH-200 dishwasher.
The line strainer should be installed in the incoming water supply line before the machine.
The line strainer has a removable screen that should be cleaned at least once a year.
UH-200B, UH-200
To clean the line strainer:
1. Turn the main water supply to the
machine off.
2. Push the POWER pushbutton off,
if machine is ON, to enter auto-shutdown.
Otherwise, turn machine on then off.
This will bleed pressure off water line.
3. Remove the retaining nut from the line
strainer and extract the screen.
4. Flush the screen with water. If screen
is damaged, replace the line strainer.
5. Reassemble in reverse order.
UH-100B, UH-100, UL-100
The water line strainer for the UH-100B, UH-100, UL-100 is built-in to the valve.
Refer to Section 8.2.3, Fill/Rinse Water Solenoid Valve, page 95, for instructions on valve repair.
8.2.3 Fill/Rinse Water Solenoid Valve
UH-200B, UH-200
The 1/2" water solenoid valve is both a fill valve when the machine is turned on and a final rinse
valve during the final rinse. The valve coil is 120VAC. A repair kit is available to rebuild the
internal parts of the assembly.
To remove the valve assembly:
1. Turn the main water supply to the
machine off.
2. Push the POWER pushbutton off,
if machine is ON, to enter auto-shutdown.
Otherwise, turn machine on then off.
This will bleed pressure off water line.
3. Remove the lower front panel from the
dishwasher. The valve assembly is
located on the left front side.
4. Disconnect valve discharge hose.
5. Remove (2) valve bracket retaining
bolts.
6. Pull valve assembly forward and
out of the dishwasher.
(continued next page)
Line Strainer
UH-200B, UH-200
Retaining nut
Screen
Remove bracket
retaining bolts
Pull assembly
forward and out