Part 1:
GENERAL SPECIFICATIONS
1.2 Model Numbers
UH-200B
The UH-200B is a high temperature (180
°
F/82
°
C) sanitizing machine with a built-in booster.
(40
°
F/22
°
C) rise booster is standard requiring a minimum incoming water supply temperature
of 140
°
F/60
°
C. A (70
°
F/39
°
C) rise booster is available which requires a minimum incoming
water supply temperature of 110
°
F/43
°
C. The UH-200B is a fresh water rinse machine. Final
rinse water enters the final rinse spray system under line pressure. A portion of the final rinse
water is retained for the next wash cycle.
UH-200
The UH-200 is a high temperature (180
°
F/82
°
C) sanitizing machine without a built-in
booster. It requires a minimum incoming water supply temperature of 180
°
F/82
°
C. The
UH-200 is a fresh water rinse machine. Final rinse water enters the final rinse spray system
under line pressure. A portion of the final rinse water is retained for the next wash cycle.
UH-100B
The UH-100B is a high temperature (180
°
F/82
°
C) sanitizing machine with a built-in booster.
(40
°
F/22
°
C) rise booster is standard requiring a minimum incoming water supply temperature
of 140
°
F/60
°
C. A (70
°
F/39
°
C) rise booster is available which requires a minimum incoming
water supply temperature of 110
°
F/43
°
C. The UH-100B is a fresh water pumped final rinse
machine. Final rinse water enters the wash tank and is recirculated by the wash pump. The
final rinse water is retained for the next wash cycle.
UH-100
The UH-100 is a high temperature (180
°
F/82
°
C) sanitizing machine without a built-in
booster. It requires a minimum incoming water supply temperature of 180
°
F/82
°
C. The
UH-100 is a fresh water pumped final rinse machine. Final rinse water enters the wash tank
and is recirculated by the wash pump. The final rinse water is retained for the next wash
cycle.
UL-100
The UL-100 is a low temperature (140
°
F/60
°
C) chemical sanitizing machine for use with a
sodium hypochlorite (chlorine) based sanitizer at a minimum concentration of 50 PPM (for
USA/Consult the local authority for Canada) in the final rinse. It requires a minimum
incoming water supply temperature of 140
°
F/60
°
C. The UL-100 is a fresh water pumped
final rinse machine. Final rinse water enters the wash tank and is recirculated by the wash
pump. The final rinse water is retained for the next wash cycle.