8.2.6 Pressure Transducer UH-200B, UH-200 (Cont.)
(continued from previous page)
7. Remove the transducer turning CCW out of the manifold.
CAUTION:
The transducer requires an O-ring.
Save the O-ring from the old part if you
do not have a replacement O-ring.
O-ring P/N 112731.
8.
INSPECT THE REPLACEMENT
TRANSDUCER.
The transducer pins should measure
approximately 7/16" [11mm] from
base to tip.
9. If required, carefully cut one pin at a
time using the sharpest side cutters
available to 7/16" [11mm].
10. Install an O-ring on the transducer and
screw the transducer into the manifold.
11. Make sure the transducer pins are parallel
with the manifold and point away from the
vacuum breaker. Connect the cable.
12. Restore power and water, and check for
leaks and proper operation.
13. Reinstall top and side panels.
14. Return machine to permanent location
ensuring machine is level.
15. Check supply hoses at rear of machine
to ensure they are not kinked.
To temperature/
pressure display bd.
in control cabinet
O-ring
(not included
with transducer)
Pressure
Transducer
Red stripe
indicates Pin1
Final Rinse
Manifold
Pressure
Transducer
Cable
Transducer must
be installed so
Pins point as
shown
Pin1
!! ATTENTION !!
Pressure Transducer
UH-200B, UH-200 ONLY
!
7/16"
Cut
11mm
Part 8:
COMPONENT REPAIR AND REPLACEMENT