2.9 Chemical Connections (Cont.)
2.9.1 General (All Models) Cont.
!! ATTENTION CHEMICAL SUPPLIER !!
(continued from previous page)
6. Refer to Fig. 2.9.2 showing the Fill/Chemical Dispenser Circuit Board.
7. There are (4) adjustable potentiometers.
• Fill-
2 to 40 seconds
• Detergent-
1 to 30 seconds
• Sanitizer-
1 to 30 seconds
• Rinse aid-
1 to 30 seconds
8. Two dots on one end of the potentiometer
serve as the dial pointer.
9. Turn CW to increase time setting.
NOTE:
The graduated numbers
(0-10) around the potentiometers
DO NOT
correspond to time settings.
Use them for position reference only,
not an actual time setting indication.
Refer to Sections 2.9.2 through 2.9.4 for specific adjustments and chemical
priming instructions for your model dishwasher.
10. Refer to Fig. 2.9.3. showing the recommended chemical bottle placement.
Bottles may be placed on either side of the dishwasher.
11. Bottles must be placed no farther than
6 ft. [1829mm] from the machine.
12. I.D. tags identify chemical tubing.
13. Pick-up tubes are inserted directly
in chemical bottles.
Part 2:
INSTALLATION
Figure 2.9.3
Chemical Bottle Placement
Floor
cut away
to show rear
Route chemical tubing
through rear access
hole above fill and
drain hose access
Max.
6 ft.
[1829mm]
Figure 2.9.2
Fill/Chemical Dispenser Circuit Board
FILL
DETERGENT
SANITIZER
RINSE
AID
9
1
5
6
4
3
7
2
8
0
10
9
1
5
6
4
3
7
2
8
0
10
9
1
5
6
4
3
7
2
8
0
10
9
1
5
6
4
3
7
2
8
0
10
9
1
5
6
4
3
7
2
8
0
10
DOTS
ON
END
OF
POTENTIOMETER
I
.
D
.
TAG
INSERT
PICK
-
UP
TUBE
IN
BOTTLE
PDF compression, OCR, web optimization using a watermarked evaluation copy of CVISION PDFCompressor