9.3.8. Step 8: Adjusting the Endstops
Ensure that the gate is in the fully closed position.
Slightly loosen the Torx screws on front endstop and adjust the endstop so that it sits up
against the pivot bracket of the operator. Tighten the Torx screws in this position.
If the gate has mechanical endstops in the closed position, there is no need to
adjust the front endstop on the operator.
FIGURE 36. ADJUST THE ENDSTOP
Loosen the Torx screws
Pivot Bracket
Move the front endstop
and tighten the Torx
screws
With the unit still in the override condition, move the gate leaf into the required open
position and adjust the rear endstop in the same way. Once the endstop has been
adjusted, close the gate leaf, re-engage the unit and remove the keys. The unit is now
ready to be connected to the controller.
•
The operator should never be run manually directly off a battery!
Doing so and driving the operator into in an endstop will result in
serious damage being sustained by the worm drive
• Never lubricate the worm drive