page 19
www.CentSys.com
S
ECTION
6
PREPARATION
OF
S
ITE
FIGURE 5
1 metre
1 metre
Gate in closed
position
Gate hinge
point
Gate in open position
Mark the ground
Distance Z
Mark the ground
Wall
6.2. Determine Gate Opening Angle
Use this procedure to accurately determine the gate opening angle:
6.2.1. Step 1
Close the gate and measure a
distance of one metre from the
centreline of the gate hinge.
Make a mark on the ground.
6.2.2. Step 2
Open the gate and measure a
distance of one metre along the gate
from the centreline of the gate hinge.
Make another mark on the ground.
Measure the distance on the ground
between the two marks (Z).
Using this Z-Value, determine the
gate opening angle from the table
below.
Z-Value from
To
Use gate swing angle of
1000mm
1133mm
60° - 69°
1147mm
1272mm
70° - 79°
1286mm
1402mm
80° - 89°
1414mm
1475mm
90° - 95°
1486mm
1532mm
96º - 100º
Z-Values greater than 1532mm
1
TABLE 5
1. The
VERT-X
operator is designed for a maximum gate opening angle of 100°.
6.2.3. Step 3
Gate opening angle based on Z-Value